Model 227 operation manual – Arc Machines 227 User Manual

Page 16

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION II - SPECIFICATION

2.0

ELECTRICAL

1. RATING PLATE DEFINITIONS

21) - International Protection (IP) rating. The M-227 is rated IP21 which

includes protection against a limited amount of exposure to rain (does

not make it weather proof or intended for all weather usage).

22) - The M-227 is rated as class I. No symbol is used for class I equipment.

23) - “S” Symbol indicates a welding power source which is suitable for an

environment with an increased electric shock hazard.

2. INPUT POWER, DETAIL - The M-227, as shipped standard, can operate on

the following Single Phase input AC:

Voltage

Tolerance

Freq.

Max Input Current

100 VAC

+ 32%, -10%

50/60 Hz

30 amperes

110 VAC

+ 20%, -18%

50/60 Hz

30 amperes

115 VAC

+ 15%, -22%

50/60 Hz

30 amperes

120 VAC

+ 10%, -25%

50/60 Hz

30 amperes

200 VAC

+ 32%, -10%

50/60 Hz

30 amperes

208 VAC

+ 27%, -13%

50/60 Hz

30 amperes

220 VAC

+ 20%, -18%

50/60 Hz

30 amperes

230 VAC

+15%, -22%

50/60 Hz

30 amperes

240 VAC

+ 10%, -25%

50/60 Hz

30 amperes

+/- % indicates the allowable input voltage change to maintain performance as

specified. Maximum input current is based on maximum output current at

maximum arc voltage. See section 3.1 for installation.

3. OUTPUT POWER - Straight polarity, constant current DC regulation

intended for GTAW welding only. Static characteristic of the M-227 is flat.

Minimum current Output all cases .................... = 3 Amperes DC
Maximum current Output:

Set up for 110 VAC input ............. = 100 Amperes DC continuous or peak pulse.

Set up for 220 VAC input ............. = 200 Amperes DC continuous current

225 Amperes DC peak pulse

NOTE

The M-227 is limited, by software, not to be able to be programmed for an

average current (between primary and background) of greater than 200 Amperes.

However, a peak pulse can be up to 225 amperes as long as the average does

not exceed 200 amperes.

4. CIRCUIT BREAKER - ON/OFF, two pole, 30 Ampere at 250 VAC.