3.3

ADAPTER CABLE INSTALLATION (continued)

4.

Insert the Service cable male gas quick-disconnect into the M-227 ARC

GAS OUTPUT connector.

5.

Insert the two coolant quick-disconnects into the COOLANT IN and

COOLANT OUT connectors on the CW (if being used). The cable

coolant connectors are interchangeable and it does not matter which one

goes to in or out.

3.4

WELD HEAD INSTALLATION - The weld head cable connects to the adapter

cable. Refer to the Weld Head Operation manual as you perform this installation.

1.

The male brass quick dis-connect on the adapter cable provides the electrode

power and one leg of the coolant path. Connect it to the mating female

quick dis-connect on the Weld Head.

2.

Connect the other coolant quick dis-connect and gas quick dis-connect (they

are different types and sizes) to their mates on the Weld Head Cable.

3.

After the Electrode, Coolant and Gas connectors are secure and checked,

slide the rubber boots on each line together and secure them in place. These

boots provide both a safety factor to prevent shorting to ground and also act

as a retainer to prevent the connectors from coming apart.

4.

Unscrew the CONTROL connector dust caps on both cables just before

installing. Insert the adapter connector into the head connector. Note the

positioning keyway and NEVER FORCE or use tools on the cable

connections. Using just your hand, tighten the connecting ring until the pins

are firmly seated. Screw the two dust caps together to prevent them from

swinging around.


3.5

GROUND (WELDING WORK) CABLE INSTALLATION

1.

A 50 ft Ground Cable with a “C” type clamp on one end and a Cam-lok quick

dis-connect is provided.


2.

Connect the quick dis-connect to the GROUND connector on the M-227 or

the Ground Extension Cable if one is provided.


3.

Connect the Ground Clamp to a “bare” metal surface on the Pipe to be

welded. It should be placed as close to the weld as possible.


3.7