5.7

SET UP FUNCTIONS


1. OPERATE MODE SET UP SCREENS


4. REV - Pressing the F key under this will show the current software

REVISION installed. This can be important when discussing problems or

features with an AMI representative.

NOTE

The following SET UP functions are accessed by pressing NEXT SCREEN

from the first SET UP screen.

5. Print EMM - Pressing the F key under this choice will create a Print out of

the LIBRARY contained in M-207-EMM Option (EMM must be installed).

6. AMP - TIME - This feature allows the user to change the programmable

increments of LEVEL AMPS or LEVEL TIME from 000 (whole numbers)

to 000.0 (tenths) .

NOTE

This is not on an individual WELD # basis. All WELD # will be changed

automatically. If a WELD # was originally programmed for 87.7 amperes

and this is changed to whole numbers the WELD # when accessed will then

call for 87 amperes (it will drop the digit, not round off).

7. ARC V FAULT - This feature can turn this FAULT ON or OFF. When

ON a STUB OUT will be created if the ARC VOLTAGE goes below 5 V

or a HIGH VOLTS fault if the VOLTAGE goes over 20 V . These

conditions only occur in automatic welding if something is wrong .

However, in manual welding these conditions can occur without anything

being wrong . THIS FEATURE NEEDS TO BE SET TO OFF FOR

MANUAL WELDING .

NOTE

The following SET UP functions are accessed by pressing NEXT SCREEN

from the second SET UP screen.


8. OPERATOR ID - This feature allows the Operator to enter his name into

system memory and the M-227 will record that name onto every print out

run after a weld sequence.

9. SERIAL NUMBER - This feature allows the entry of the Power Supply

Serial number into system memory and the M-227 will record that SN# onto

every print out run after a weld sequence.