Model 227 operation manual – Arc Machines 227 User Manual

Page 55

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION V - OPERATION

5.8

REMOTE PENDANT (RP) OPERATION

1. A complete understanding of system operation is needed for proper use of the

RP. All previous sections of this manual and all previous steps of this section

should be read before proceeding with RP operation.

2. The following functions and features are provided by the standard RP:

1. Sequence Start key

2. Sequence Stop key

3. All Stop key

4. Travel Jog CW key

5. Travel jog CCW key

6. Weld/Test Mode key

7. Wire Feed Mode key

8. Wire Feed Jog key

9. Wire Retract Jog key

10. Osc IN Jog key

11. Osc OUT Jog key

12. AVC UP Jog key

13. AVC DOWN Jog key

14. Primary Amp Override key

15. Background Amp Override key

16. Primary Wire Feed Override key

17 Background Wire Feed Override key 18. Arrow Up key

19. Arrow Down key

20. Special Function key

21. Next key

22. Prev key

23. Primary Pulse Time Override key

24. Background Pulse Override key

25. Primary Travel Speed Override key

26. Background Tvl Override key

27. Primary AVC Override key

28. Background AVC Override key

29. Osc Amplitude Override key

30. Excursion Time Override key

31. IN Dwell time Override key

32. OUT Dwell time Override key

33. 8 character digital status display

2. Items 1 to 13 above are duplicates of keys contained on the M-227 panel. They

work exactly the same as the keys on the panel. When the RP is connected

these keys and the identical ones on the M-227 panel are active at the same

times. Pressing either key will perform the function desired .

3. The 8-charter digital display is used to indicate to the operator what particular

mode or area of a weld schedule the system is in.

When the M-227 is first turned ON the RP display will say NO SEQ. This

indicates to the operator that no weld schedule has been selected. When a

schedule is selected the display will show 001 TEST. This indicates that PASS

# 1 of a Weld Schedule has been called up and that the system is in TEST mode.

At other times it may indicate WELD or FLT depending on system status.

NOTE

If the power was turned off while a weld schedule was displayed the

system will power up with that schedule displayed again. The NO SEQ display

applies to power ON when power OFF occurred without a weld schedule

displayed.