SECTION V - OPERATION

5.9

ROTATION CALIBRATION

5. Create or recall from the LIBRARY the appropriate Weld Schedule and

connect the Weld Head to be calibrated. Insure that the system is SAFE to

rotate and that the System Mode is in TEST. Note the starting position of the

Weld Head and Press Sequence Start. At the end of the Sequence the weld

head should have rotated the programmed amount.

6. If it has not rotated or moved the correct distance then adjust the Weld Head

Rotation Cal Potentiometer

7. Repeat 5 and 6 until the head is calibrated.

5.10

WIRE FEED CALIBRATION

NOTE

For proper operation, weld head Wire Feed speed must be calibrated for the

power supply it is connected to. If weld heads are switched they must be re-

calibrated on that system before welding commences.

1. Insure that the weld head is connected per section III and the Weld Head

manual. Wire Feed calibration is done by feeding the wire and measuring actual

speed. Before proceeding CHECK THAT THE HEAD IS FREE TO FEED

WIRE SAFELY

2. To manually calibrate the user will need to have a Weld Schedule in the Library

programmed in accordance to the Calibration Procedure contained in the

operation manual for the particular Weld Head being used

3. A MANUAL calibration schedule will always be run in TEST Mode and usually

contains the following:

PRE-PURGE-POST

UP-SLOPE-DOWN

ROT-DLY

000

00.0 00.0

CCW 00.0

STR-WFDLY-STP

RETRACT

T/MODE

00.0 00.0

0.0

AUTO

LVL-TIME

PRI-AMP-BCK

PRI-PULSE-BCK

1 060

000 000

0.00 0.00

LVL PULSE

ROT

PRI--RPM--BCK

1 OFF

OFF

0.0 0.0

LVL PRI-WF-BCK

01

100 100



5.15