7.5

GENERAL MAINTENANCE INSTRUCTION

WARNING

Always disconnect the AC power cable from the line voltage before attempting to

work with this welding power supply.


1. AIR FILTER - The M-227 power supply has one (1) foam air filter. Inspect this

air filter regularly. The foam filters may be washed in water and detergent, dried

and reused or replaced. Do not operate unit without filter in place. There is a

similar filter on the M227/207-CW or M207-CW Cooling Unit that requires the

same inspection and cleaning.


2. COOLANT - The water tank in the optional M227/207-CW OR M207-CW unit

holds approximately three (3) U.S. gallons. Check water level periodically. Using

different weld heads will remove water from tank over a period of time. Fill the

tank per instructions of Section VIII.


3. Cleaning exterior and interior surfaces - Prolonged use in dusty shop or outside

environments may cause the outside surfaces to accumulate a coating of dirt and

dust. Do not use shop air (usually too wet) to blow dust particles away from

panels. Either wipe it off with a damp cloth or use a vacuum cleaner with a soft

brush . Where a vacuum brush cannot reach, use clean, soft paint brush and then

vacuum.

CAUTION

Always disconnect the power input cable from the junction box or wall-plug

before cleaning.


DO NOT USE ANY SOLVENTS, SPRAY-ON CLEANERS OR WATER on

any of the inside parts. All outside surfaces may be cleaned with a soft cloth or

sponge, damp, NOT SOAKED, with a mild detergent solution.

4. INPUT/OUTPUT PANEL CONNECTIONS - Periodic inspection of the M-227

panel and cable electrode, gas and water return quick-disconnects should be

performed. Damaged, dented or deformed connectors may cause poor or unsafe

operation and water or gas leakage.