SECTION VII - CALIBRATION

7.4

TORCH OSCILLATION (OSC) AMPLITUDE CALIBRATION Cont.


1.

Select Weld Schedule Number ____ and verify that the FIRST PASS

it is programmed as follows:

LVL

1

TIME

0

PRI-AMP--BCK
100 100

PRI-PULSE-BCK
0.00 0.00

LVL

1

PULSE

OFF

ROT

OFF

PRI--IPM-BCK

0.00 0.00

LVL

1

PRI-WF-BCK

000 000

PRI-AVC-BCK

10.0 10.0

AVC MODE

CONT

LVL

1

OSC AMPL

.500

IN EXC OUT

0.5 0.5 0.5


PRE-PURGE-POST

3 3

UP-SLOPE-DOWN

0.0 0

ROT--DLY

CW 1.0

STR WFDLY STP
0.0 0.0

RETRACT

0.0

T/MODE

MAN

STLV

25

OSC

OFF

STR AVDLY STP
1.0 0.0

STR/ MODE

TOUCH

RESPONSE

3

2. Insure that the Torch is free to Oscillate without obstructions.

3. Set the WELD/TEST mode (RP or Panel) to TEST. Using Jog Keys center Torch

in the middle of its stroke.

4. Using the Dial Caliper prepare to measure the total movement of the Torch from

its furthest IN position (toward the Head) to its furthest OUT position. How this

can be done will vary from Weld Head Model to Weld Head Model.

5. Press Sequence Start and after prepurge measure the full Oscillator movement. It

should be 0.500 inch +/- 0.005. If out of tolerance adjust TR4 on the center plate.

6. When measurement and adjustment is complete press All Stop.







7.6