MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION VIII - OPTIONS

8.2

M-227-EMM EXTERNAL MEMORY MODULE


1. The M-227-EMM is used to TRANSFER a COPY of the library of one M-

227 to another M-227 to maintain identical libraries for multiple system

users. It is also used as a security device to retain a copy of the library which

cannot be changed accidentally.

WARNING

Always turn the power supply OFF before making any cable or connection

changes to the M-227 power supply.


2. To install the EMM, turn the M-227 OFF. The EMM has a connector on

one side of the module. This connector should be inserted into the slot on the

side of the M-227 labeled EMM. It is keyed and can only be inserted one

way. When installed, turn the M-227 ON and perform the desired

TRANSFER or RECEIVE functions as described in Section VI of this manual.


3. When finished with the EMM it should be stored in a secure, dry location away

from any large magnetic or electrical sources.


4. The EMM uses a type of memory that does not require batteries and has an

unlimited shelf life. However, it does have a limited number of erase cycles.

Erasing occurs anytime you are COPYING from a M-227 to the EMM.

Erasing of the EMM memory does not occur when you are TRANSFERRING

from the EMM to the M-227. Eventually the EMM will require replacement.

However, this is not anything to be particularly concerned with. Even if you

erased the EMM every day (very high usage) it would last 27 years.


5. A copy of the EMM Library can be printed by using the EMM PRINT

function on the SET UP screen, see Section 5.6.1.

CAUTION

The M-227-EMM and the M-207-EMM look alike (although labeled

differently). Do not confuse them and attempt to use an M-227-EMM with a

M-207A.