MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION V - OPERATION

5.2

USE OF NEXT/PREV SCREENS/LEVELS


6. PURGE - SLOPE - ROT DELAY = Displays the time for Prepurge,

Postpurge, Upslope, Downslope Rotation Direction and Rotation Start


7. WF DELAY - RETRACT - T/MODE - OSC MODE = Displays settings

for Wire Feed Start Delay, Stop Delay, Wire Retract Time, Timer Mode and

Osc Mode


8.

AVC DELAY - START MODE - RESPONSE - START LEVEL =

Displays settings for AVC Start Delay, Stop Delay, Response and Start Level.


Pressing the NEXT SCREEN key will advance the display in the above order.

When viewing screen 2 to 8 (above) pressing the PREV SCREEN key will

reverse the order.

The weld schedule can be programmed to have up to a 100 levels of screen 2, 3, 4

and 5. When viewing screen 2, 3, 4 or 5 the operator can press the NEXT LEVEL

key to view the values for the next level for those same functions (if programmed).


When displaying level 2 or greater, pressing the PREV LEVEL key will then

display the previous level.


Pressing the NEXT SCREEN or PREV SCREEN key after using the NEXT

LEVEL or PREV LEVEL key will display the NEXT SCREEN for that LEVEL,

except if the next screen is 1, 6, 7 or 8, these screens are the same for all levels.


Reference figure 7 for a flow chart on the use of NEXT/PREV SCREEN and

LEVEL keys.


5.3

WELD SCHEDULE SELECTION


The following describes how to select a weld schedule from the LIBRARY. The

Operate Mode switch must be in the OPERATE or PROGRAM position. Be sure

to have read section 5.2 (use the Next/Prev keys) before proceeding.

1. The STATUS Screen of 5.1 should be displayed. If not press the C key until

until the STATUS screen appears.


2. Press the LIB key and the following display will appear:



5.3