SECTION VII - CALIBRATION


7.8

MISCELLANEOUS MAINTENANCE ITEMS

1. BATRAM - The system BATRAM has a life of from 2 to 5 years. The

following describes what happens to the BATRAM settings and functions

when the BATRAM is replaced:

1.

System Hours and Arc Hours - Will reset to 0.

2.

Day/Date information - Will have to be reset.

3.

Last Language used - Will default to English until reset.

4.

Remote Sensor set ups will have to be reset.

5.

Whole or Tenth increments for Amps and Level Time will reset to whole.

6.

Operators Name will clear.

7.

Power Supply Serial Number will clear.


Replacing the BATRAM requires accessing the inside of the M-227. A

complete replacement procedure is available in the M-227 Maintenance

Manual.


2. RS232 COMMUNICATIONS


The M-227 can shut down the RS232 port on it own if it detects

non-intelligent information on it. This can be caused by ambient

light or improper set up. The RS232 port will not be re-activated

until the power has been re-set. If you are having problems with

RS232 communications, re-set the power and try again.

NOTE

Always keep the plastic dust covers on the RS232 port when not in use.