Model 227 operation manual – Arc Machines 227 User Manual

Page 74

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION VII - CALIBRATION

7.2

CURRENT CALIBRATION (continued)


13. Wait for machine to advance to and even level or 10 Amps.

14. During Weld Seq. Even Levels the DMM should read as follows:

Center Plate Test Points = 0.20 VDC +/- 0.001 VDC.

(0.199 VDC to 0.201 VDC)

AMI External Shunt = 10 mv DC +/- 0.025 mv DC

( 9.97 mv to 10.02 mv )

If out of tolerance adjust the “Current Off Adj.” Current offset trimming

potentiometer adjusting screw on the Center Plate.


15. Repeat steps 13 and 14 until no adjustments are required.

16. Press the SEQ STOP key.

17. After Postpurge turn the power off, remove all test leads. If calibration is

complete lower the computer cover and install the retaining screws



7.3

ARC VOLTAGE CONTROLLER (AVC) CALIBRATION

A weld schedule is required for AVC calibration. The first time calibration is

performed this schedule will have to be CREATED. Step 1 (next page) has a place

for writing in the Weld # after it has been created.

NOTE

The adjustment for AVC Calibration is located on the Center Plate under the

computer cover (front panel housing). Turn the Power OFF and unscrew the two

computer cover retaining screws in the front. Lift up on the cover and expose the

center plate. Prop the cover up so it will not fall but make sure you can still operate

the system. Locate the adjustment screw labeled “TR3” and turn the power back ON..

1. Select Weld Schedule Number ____ and verify that the FIRST PASS

it is programmed as follows:

LVL

1

TIME

20

PRI-AMP--BCK
100 100

PRI-PULSE-BCK
0.00 0.00

LVL

1

PULSE

OFF

ROT

OFF

PRI--IPM-BCK

0.00 0.00

LVL

1

PRI-WF-BCK

000 000

PRI-AVC-BCK

10.0 10.0

AVC MODE

CONT

7.4