4.3

WELD SEQUENCE

8.

EVENT 8: RETURN TO HOME AND RESET - When POSTPURGE is

complete the gas will shut off. When the gas shuts off, Weld Heads with

“Return to Home” functions (M-9, M-95, M-79) will then have the rotor

automatically return to the open position for removal. The System will then

reset and be ready to make another weld.

4.4

PANEL KEYS - The following are descriptions of all active operating keys

contained on the system Main Panel (see figure 6):

1.

ALL STOP KEY - Active only during weld sequence in test or weld mode.

When pressed it will stop the sequence, turn off the arc with no downslope

and start the postpurge process (see 4.3 event 7).

2.

C KEY - Used for screen clear or cancel, it will end (without storing) the

screen being displayed and return to the beginning of any step. The screen

will prompt the operator to indicate what will happen if the C key is pressed.

3.

CE KEY - The Clear Entry key is used to clear numbers entered with the

numeric keys before the ENTER key is pressed. Use this key when a mistake

is make using the numeric keys.

4.

ENTER KEY - Used at the end of each step to indicate completion and to

move to the next step or screen.

5.

F KEYS - These are function keys numbered 1 to 16. Each key is aligned

with a portion of the display and are used to activate, cycle or alter the item

displayed above or below it. Each key will alter different functions

depending on whet screen is being displayed. Use of the F keys is always

prompted by the screens.

6.

L KEY - The M-227 is multi-lingual. Pressing this key will change the

display from English to French to German, etc.. The L key is always active.

7.

LIB KEY - Used to access the LIBRARY (weld schedule memory/storage).

8.

MANUAL PURGE KEY - Active at all times. Used for manually turning

on the gas solenoid. When ON, the gas solenoid will be energized and it

will stay ON until this key is manually pressed again.

9.

METER KEY - Only one of the displays is used as a BAR GRAPH METER

during Welding. Limited functions are shown. Use this key to access the

desired meter function. Remember that meter readouts are provided for

functional troubleshooting only. They are not intended for verification of

system performance.