MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION V - OPERATION

5.8

REMOTE PENDANT (RP) OPERATION

3. (continued)

When the weld sequence is started the display will indicate progression through

PURGE, UPSLOPE, LVL 01 (etc.), DOWNSLOPE and then

POSTPURGE.


4. The Override Keys allow the operator to change Amps, Volts, TVL, OSC and

Wire Values (with-in set limits) . After a Pass is called up pressing one of these

keys will change the display to show the value of that function. Using the Arrow

Up key will then increase the amount . Using the Arrow Down key will then

decrease the amount.The same Operation can also be done DURING SEQUENCE

as well.


Overridden values only stay as long as that pass is displayed. If another pass is

called up and then the original one is called up again the values will be as

originally programmed, not as previously overridden. With the Operate Mode

key in PROGRAM it is possible to save or MODIFY the original parameters

with the new overridden values . See Special Function Key operation (step 5)

for more details.


Using the Override Keys only OVERRIDES the function value in the

LEVEL displayed . During Sequence you cannot Override a value in

another LEVEL . Before Sequence it can be done by use of the MAN ADV

special Function. See Special Function Key operation (step 5) for more details.


5. SPECIAL FUNCTION KEY - The Pendant Special Function key allows access

and manipulation of many additional functions. This feature works ONLY

WHEN NOT IN WELD SEQUENCE. Each time the Special Function key is

pressed the display will change in the following order :

1. PASS - This allows the user to select the next or previous pass in the Weld

Schedule . Pressing the NEXT Key will access the next pass, if there is

one. Pressing the PREV Key will access the last pass, if there is one .

When pressed the display will leave the Special Function and show the

Weld pass # and System mode (002 TEST) as previously described.

2. PURGE - Press the NEXT Key to manually change the state of the Gas

Solenoid . It will turn ON or OFF depending on its condition . Press the

NEXT Key again to return the Gas Solenoid to its original state . You can

continue to cycle the Solenoid in this way until another function is chosen

(like jogging, etc.).

5.12

Advertising