Model 227 operation manual – Arc Machines 227 User Manual

Page 42

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION IV - SYSTEM FUNCTIONS

4.7

SENSOR 1, 2, 3 FAULTS

The M-227 has 3 separate inputs that the user can define for creating a fault

condition based on some external problem. The most common is connecting a gas

analyzer(s) to the M-227 to detect excessive Oxygen in the I.D. purge of a weld.

The user must make these connections and uses the SET-UP screen (see 5.8) to

define what a fault is for this external input.

4.8

SET-UP FUNCTIONS

The following SET-UP functions provide some customizing and calculating

features to enhance system performance:

1.

CALCULATE - Calculates TUNGSTEN LENGTH, IPM to RPM

conversions and WELD TIME.

2.

WELD-SELECT - The M227-RP may select up to 4 pre-determined weld

schedules from memory. This function defines the schedules that are picked.

3.

COOLANT FAULT - Used to enable or disable Coolant Fault whether or

not a M227/207-CW or M207-CW is connected.

4.

REV - Used to display the SOFTWARE REVISION of a particular M-227.

Depending on intended use, M-227’s may have different software revisions.

5.

PRINT EMM - Used to print a copy of the EMM memory.

6.

AMP - TIME - Used to change the last significant digit of Level Current or

Level Time from whole numbers to tenths (000 to 000.0).

7.

ARC V FLT - Used to de-activate STUB OUT and HIGH VOLT faults

These faults are usually needed to be turned off for manual welding.

8.

SENSORS - Activates and defines EXTERNAL Fault inputs (see 5.8).

9.

PRINTER - Used to select AUTO or MANUAL print mode.

10. OSC SPEED - Used to set the speed that the OSC IN Key and OSC OUT

key move the Oscillator Steering.

11. DATE RESET - Used to reset the DATE.

12. AVC JOG SPEED - Used to set the speed of the AVC JOG UP and AVC

JOG DOWN. Primarily used to refine Touch Start Operation.

13. OPERATOR I.D. - Allows the Operator to enter his name or ID number.

Once entered it will be printed on all copies of weld schedules.

14. POWER SUPPLY SERIAL NUMBER - Allows entry of Power Supply

Serial #. Once entered it will be printed on all copies of weld schedules.

4.16