Model 227 operation manual – Arc Machines 227 User Manual

Page 83

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION VIII - OPTIONS

8.0

INTRODUCTION

The following are installation and operation instructions for some M-227 options.

WARNING

Always turn the power supply OFF before making any cable or connection changes to

the M-227 power supply.

8.1

M227/207-CW & M207-CW COOLING UNIT SPECIFICATIONS/INSTALLATION

1. Specifications -

1. AC Input Power - supplied from the M-227 power supply.

2. Coolant capacity - 3 gallons (11.4 liters).

3. Circulation - 0.3 GPM (1.1 lpm) with most M-9 Heads.

2. Physical Construction -

1. Material - aluminum cabinet/Polyethylene tank.

2. Height

- 14.00 inches (355.6 mm)

3. Width

- 22.75 inches (577.9 mm)

4. Depth

- 19.25 inches (489.0 mm)

5. Weight

- 70 lbs. (31.75 kg) M227/207-CW filled

- 50 lbs. (22.7 kg) M207-CW filled

3. Pump- Both M227/207-CW & M207-CW water pumps have a built-in pressure

regulators set at 60 PSI, along with an external flow rate FAULT detect switches.

4. Installation

1. Insure that the M-227 is OFF, remove the power cable from the M-227

and set the CW ON/OFF switch to the OFF position.

2. The cooling unit is shipped dry and requires 3 gallons (11.4 liters) of

CLEAN DISTILLED or DE-IONIZED water. In areas where freezing

temperatures are expected, add 2 gallons (7.6 liters) of CLEAN

DISTILLED or DE-IONIZED water and 1 gallon (3.8 liters) of pure

ethylene glycol. DO NOT USE AUTOMOTIVE ANTI-FREEZE


NOTE

All cooling systems are subject to problems from mineral buildup, algae and bacteria.

Frequent changes of coolant and flushing of the system are necessary to keep any

cooling system running efficiently. Frequency of changes is strictly dependent on the

environment and quality of coolant used. Monitor your cooling system carefully and often.





8.1

Advertising