Model 227 operation manual – Arc Machines 227 User Manual

Page 27

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION IV - SYSTEM FUNCTIONS

4.0

INTRODUCTION

The M-227 is intended for use with AMI orbital welding heads and has functions

designed for these weld heads. This section describes what these functions are and

may, where needed for clarification, indicate how they are commonly (but not

always) used.

Step 4.1 is a general description; the remaining steps describe, in more detail, the

items of step 4.1. Only FUNCTION is discussed here. Details of function ranges and

tolerances can be found in section II of this manual and the AMI Specification No.

227. Details about operating these functions can be found in section V.

4.1

FUNCTIONAL DESCRIPTION, GENERAL

1.

LIBRARY - The heart of the M-227 is its MEMORY. The values of each

function, for a given weld, are only programmed one time. After that the M-

227 will store the function values (for that weld) by WELD SCHEDULE

NUMBER (#) and description.

When a particular weld type is needed to be made the Operator can locate it

in the WELD SCHEDULE LIBRARY by description or by weld schedule

number (#).

2.

WELD SEQUENCE AND LEVELS - Selected weld schedules are started

by manually initiating the SEQUENCE START. Once the sequence is

started the system operation can be totally automatic.

In addition to functions to start and stop the weld, the weld sequence

includes the ability to preset changes in function values and modes. These

changes are called LEVELS and as many as 100 levels can be used for each

weld sequence. All weld schedules start with (and must have) Level 1.

If preset changes are desired they will be set in LEVELS 2, 3, ETC. The

LEVELS advance from 1 to 2, 2 to 3, etc. automatically as a function of

time, or they can be advanced by the Operator manually.

3.

CURRENT SOURCE AND CONTROL - The M-227 is a pulsed, 225

ampere peak, constant current, straight polarity, GTAW power source. The

current value(s) can be set between 3 and 225 Amps.

NOTE

The M-227 is limited, by software, not to be able to be programmed for an

average current (between primary and background) greater than 200 Amperes.

However, a peak pulse can be up to 225 amperes as long as the average does

not exceed 200 amperes.

4.1