Model 227 operation manual – Arc Machines 227 User Manual

Page 32

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION IV - SYSTEM FUNCTIONS

4.3

WELD SEQUENCE

4.

EVENT 4: FULL LEVEL FUNCTIONS -

3. LEVEL 1 PRIMARY PULSE TIME - If the LEVEL 1 PULSE MODE

is ON this function will now be timing the Primary pulses (see Event 3).

4. LEVEL 1 BACKGROUND PULSE TIME - If the LEVEL 1 PULSE

MODE is ON this function will now be timing the Background pulses.

5. LEVEL 1 PRIMARY AMPS - After UPSLOPE the system will be

regulating this programmed value of current each time the system goes to

Primary Pulse either using the Level 1 Primary Pulse Time or the Level 1

Osc Dwell Time if the Level 1 Pulse Mode is in SYNC.

6. LEVEL 1 BACKGROUND AMPS - If the LEVEL 1 PULSE MODE

was programmed to ON or SYNC, the system will be regulate the

Level 1 Background current value after each Level 1 Primary pulse.

7. LEVEL 1 TRAVEL MODE - After the TRAVEL START DELAY time

is complete the Travel will function in one of these programmable modes.

OFF = Will prevent rotation from occurring.

CONT = Runs the travel at the PRIMARY-RPM speed only,

regardless of PULSE MODE.

STEP = Will pulse the travel between the PRIMARY-RPM and

BACKGROUND-RPM speed. If the TRAVEL MODE is in

STEP but the PULSE MODE is in OFF then only PRIMARY will

occur (without pulsing there are no background functions).

8. LEVEL 1 PRIMARY-RPM - After the Travel Start Delay time is

complete the travel function will begin. If the Level 1 Travel Mode is

programmed to CONT the travel will be rotating the arc at the Primary-

RPM rate continuously regardless of any pulsing. If the Travel Mode is

STEP it will rotate the arc at the Primary-RPM speed each time the

system goes to PRIMARY.

9. LEVEL 1 BACKGROUND RPM - If the LEVEL 1 PULSE MODE is in

ON or SYNC and the TRAVEL MODE is in STEP the system will

rotate the arc at the BACKGROUND-RPM each time the system goes to

a BACKGROUND pulse.

NOTE

Travel direction is programmable CLOCKWISE or COUNTER-

CLOCKWISE. After the Travel Start Delay the Head will rotate in the

programmed direction. The direction is not programmable by LEVELS.

4.6

Advertising