Arc Machines 227 User Manual

Page 53

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E


SECTION V - OPERATION

5.7

SET UP FUNCTIONS


2. PROGRAM MODE SET UP FUNCTIONS - If the System Mode Key is set to

PROGRAM these additional functions can be shown after the first three SET

UP screens, press the NEXT SCREEN key to access.

1. SENSORS - The M-227 FAULT detection system has an EXTERNAL input

feature that allows the user to monitor up to 3 external functions (such as an

Oxygen Analyzer) and create a M-227 FAULT if that external feature

should fail .


Pressing the F key under this will allow the user to turn any or all of the 3

Sensors ON and select whether the FAULT should occur with a LOW input

signal or a HIGH input signal. Reference AMI drawing 45B072514 for pin

connections and electrical signal information about HIGH and LOW.


2. PRINTER MODE - The M-227 can be set up to make a print out of the

WELD # automatically (AUTO) after every Sequence. If set to MANUAL

print will only be made if the PRINT key is pressed after a weld sequence.

NOTE

The following SET UP functions are accessed by pressing the NEXT

SCREEN key from the fourth SET UP screen.

3. OSC JOG - Use this feature to set the OSC STEERING speed. Weld

Head models with an OSC function can very as to the motor speed and

sensitivity when trying to steer. This feature is used to adjust the

movement to optimum for the model being used.


4. DATE RESET - Use this feature to reset the date. Usually required after

the BATRAM has been replaced (see section VII).


5. AVC JOG SPEED - Use this feature to set the AVC UP JOG SPEED and

the AVC DOWN JOG speed. Weld Head models with an AVC function

can very as to the motor speed. This can cause variations in the Touch

Start function. Use this feature to adjust the jog speeds (up and down) to

achieve the best Touch Start performance for the model being used.