Model 227 operation manual – Arc Machines 227 User Manual

Page 58

Advertising
background image

MODEL 227

OPERATION MANUAL

Doc # 740063 Rev E

SECTION V - OPERATION

5.9

ROTATION CALIBRATION

NOTE

For proper operation, Weld Head rotation speed must be calibrated for the power

supply it is connected to. If weld heads are switched they must be re-calibrated on

that system before welding commences .

1. Insure that the weld head is connected per section III. Rotation calibration is

done by moving the torch and measuring actual speed. Before proceeding

CHECK THAT THE WELD IS FREE TO ROTATE SAFELY.

2. To manually calibrate the user will need to have a Weld Schedule in the Library

programmed in accordance to the Calibration Procedure contained in the

operation manual for the particular Weld Head being used.

3. A MANUAL calibration schedule will always be run in TEST Mode and usually

contains the following:

PRE-PURGE-POST

UP-SLOPE-DOWN

ROT-DLY

000 000

00.0 00.0

CCW 00.0

STR-WFDY-STP

RETRACT

T/MODE

00.0 00.0

0.0

AUTO

LVL TIME

PRI-AMP-BCK

PRI-PULSE-BCK

1 ***

000 000

0.00 0.00

LVL

PULSE

ROT

PRI--RPM--BCK

1

OFF

CONT

*** ***

LVL PRI-WF-BCK
1

000 000

LVL TIME

PRI-AMP-BCK

PRI-PULSE-BCK

2 005

000 000

0.00 0.00

LVL

PULSE

ROT

PRI--RPM--BCK

2

2

OFF

0.0 0.0

4. LEVEL 1 TIME needs to be set for the time it will take to rotate ONE

REVOLUTION at the selected LEVEL 1 PRI--RPM rate. The RPM rate is

usually set at a rate that the head is most frequently used at

LEVEL 2 is added with ROTATION turned OFF. This is to allow the operator

time to see if 1 revolution was completed before the “Return to Home”

functions engages at the end of the Sequence. LEVEL 2 CAN BE OMITTED

FOR WELD HEADS THAT DO NOT HAVE A RETURN HOME

FUNCTION .

5.14