7 softkey setup, 8 how to use alphanumeric keypad, 9 indicator operations – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. E - Version 2.5 User Manual

Page 11

Advertising
background image

Introduction

5

1.7

Softkey Setup

Softkeys offer additional ways to access features associated with the Counterpart. To access the softkey setup
parameter, go to

Menu/Setup/Config/Feature/Softkeys

.

Select information for each softkey and press

TARE

(

Enter)

key after each entry and then press

SaveExit

softkey. To

exit back out of the unit, press the

MENU SETUP

key twice without saving changes.

Note

Softkeys set for either Display Tare or Display Accum will automatically time out and revert to the normal
active display after 10 seconds.

1.8

How to Use AlphaNumeric Keypad

Counterpart has the ability to use alpha characters along with numeric characters. Use the following steps to
change to alpha characters:

1. Select a key labeled with the value desired.

2. Push until the desired value appears, e.g. 2 abcABC.

3. Move to the next letter and push until that value appears.

4. If the next letter is the same key, push the right arrow (PRINT) to move over to the next selection.

5. When complete, push

TARE(Enter)

to save.

1.9

Indicator Operations

Basic Counterpart operations are summarized below.

Toggle Gross/Net
Press the

GROSS/NET

key to switch the display mode from gross to net or from net to gross. If a tare value has been

entered or acquired, the net value is the gross weight minus the tare. If no tare has been entered or acquired, the
display remains in gross mode.

Gross mode and net mode is indicated by the annunciator on the display.

Toggle Units
Press the

UNITS TOGGLE

key to switch between primary, secondary, and tertiary units.

Zero Scale

1. While in gross mode, remove all weight from the scale and wait for the standstill annunciator (

).

2. Press the

ZERO

key. The zero annunicator is displayed to indicate the scale is zeroed.

Acquire Tare

1. Place a container on the scale and wait for the standstill annunicator (

).

2. Press the

TARE

key to acquire the tare weight of the container.

3. The

Net

annunciator will be enabled.

Remove Stored Tare Value

1. Remove all weight from the scale and wait for the

standstill

annunciator (

).

2. Press the

TARE

key. The display shifts to gross weight and the Gross annunciator is displayed.

Keyed Tare

1. Key in the value of the container.

2. Press the

TARE

key.

3. The

Net

annunciator is displayed.

Print
Press the

PRINT

key to print either the Gross, Net, Total or Count format.

The default format is a 2.25 x 4.5 inch label.

1. Wait for standstill annunciator (

).

2. Press

PRINT

key to send data to the serial port.

If the standstill annunciator is not present, the

PRINT

key command is executed if the scale comes out of motion

within three seconds.

Advertising