Counterpart Counting Scale Indicator

Command

Description

Supported Ticket Formats

<G>

Gross weight, current scale

GFMT, NFMT, TOTALFMT,
PALFMT, CFMT, ACCFMT
HDRFMT1, HDRFMT2

<G#n>

Gross weight, scale n

<N>

Net weight current scale

<N#n>

Net weight, scale n

<T>

Tare weight in displayed units. Add four before bracket to print header

<T#n>

Tare weight, scale n

<A>

Accumulated weight, current scale

<A#n>

Accumulated weight, scale n

<AC>

Number of accumulations, current scale (5-digit counter)

<AC#n>

Number of accumulations, scale n

<AD>

Date of last accumulation, current scale

<AD#n>

Date of last accumulation, scale n

<AT>

Time of last accumulation, current scale

<AT#n>

Time of last accumulation, scale n

<UID>

Unit ID number

<CN>

Consecutive number

<C>

Piece count, current scale

<C#n>

Piece count, scale n

<NLnn>

New line (nn = number of termination (<CR/LF> or <CR>) characters)*

<SPnn>

Space (nn = number of spaces)*

<SU> or <WA>

Surpress unis. Toggle weight data format (formatted/unformatted)**

<TI>

Time

<nnn>

ASCII character (nnn=decimal value of ASCII character). Used for
inserting control characters (STX, for example) in the print stream.

<DA>

Date

<TD>

Time & Date

<H1>

Header 1

<H2>

Header 2

<IDC>

Loaded ID Code - 32 characters maximum

<IDD>

Loaded ID Description - 32 characters maximum

<IDLC>

Loaded ID Location - 12 characters maximum

<IDP>

Loaded ID Part Number - 32 characters maximum

<IDLT>

Loaded ID Lot - 32 characters maximum

<IDU>

Loaded ID Units - 1 character maximum

<IDT>

Loaded ID Tare - 9 characters maximum (range 0.0 to 9999999.0)

<IDW>

Loaded ID Unit Weight - 9 characters maximum (range 0.0 to
9999999.0)

<IDQ>

Loaded ID Quantity - 11 characters maximum (range -2000000000 to
2000000000)

<TTLV>

Totalization Value - 11 character maximum (range -2000000000 to
2000000000). When not in totalization mode, the value will be 0.

<TTLC>

Totalization Count - 4 characters maximum. When not in totalization
mode, the value will be 0.

<TTLW>

Print totalized weight. When not in totalization mode, the value will be 0.

<WA>

Suppresses all (units, decimal, leading, spaces)

<WLU>

Without leading spaces and units, decimal point is still applied.

<WU>

Suppresses units but leaves leading spaces and decimal point.

Table 7-1. Print Format Commands

Advertising