Gross, net, piecent, %rel, Sub-menu – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. E - Version 2.5 User Manual

Page 53

Advertising
background image

Configuration

47

Gross, Net, Piecent, %REL

GROSS

NET

PIECECNT

%REL

APPLIES TO GROSS, NET, PIECECNT, & %REL

SOURCE

LIST OF

SCALES

VALUE

number

TRIP

LOWER

HIGHER

OUTBAND

INBAND

BANDVAL

number

If TRIP=

INBAND or

OUTBAND

If TRIP=

HIGHER or

LOWER

HYSTER

number

PREACT

OFF

ON

LEARN

If PREACT=

ON or

LEARN

PREVAL

number

PRESTAB

PCOUNT

PREADJ

number

If KIND=

% RELSP

RELNUM

1-6

DIGOUT

NONE

1-4

SENSE

NORMAL

INVERT

ON

HIDE

OFF

ACCESS

PSHPRNT

OFF

ON

WAITSS

PSHTARE

OFF

ON

PSHACCM

OFF

ON

NQUIET

BATCH

OFF

ON

If PREACT

=

LEARN

Sub-menu

Figure 3-20. Gross, Net, Piecent, %REL Sub-menu

Parameters

Choices

Description

SP CFG

SETPT 1
SETPT 2-6

Specifies the settings for GROSS, NET, PIECECNT, % REL, delay, waitss, counter and
inmotion used by setpoints 1 through 6.

BATCHING

OFF
AUTO
MANUAL

Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run. MANUAL
requires a Batch Start softkey before the batch sequence can run. AUTO allows batch
sequences to repeat continuously.

SP CFG subenu

SETPT1-6

OFF
GROSS
NET
PIECECNT
%REL
DELAY
WAITSS
COUNTER
INMOTION

Specifies the setpoint kind.
GROSS, NET, PIECECNT, and %REL setpoint kinds can be used as either batch or continuous
setpoints. DELAY, WAITSS, and COUNTER setpoint kinds can only be used in batch
sequences.
The INMOTION setpoint kind can only be used as a continuous setpoint.

Table 3-17. Scale Setpoint Menu Parameters