9 display menu – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. E - Version 2.5 User Manual

Page 58

Advertising
background image

52

Counterpart Counting Scale Indicator

3.9

Display Menu

There are three display settings on the Counterpart.

0-100%

50

Negative

Positive

ID

DISPLAY

TEST

SETUP

AUDIT

CALIBR

SETPTS

CONTRAST

BRIGHT

IMAGE

100

0-100%

Figure 3-24. DISPLAY Menu

Setting the display parameters from this top level menu is temporary. After a power cycle, the values will revert to
their previous values. Changes made to these parameters through the CONFIG menu are kept through a power
cycle.

DIG I/O

LOOP
DIO 1
DIO 2
DIO 3
DIO 4

Tests your digital I/O ports. If they are functioning, PASS is displayed. If they are not functioning,
FAIL is displayed.

WARNING

Note

Both inputs and outputs are active low. They go to a ground state when active.

The I/O ports become activated when the test is performed. Make sure
any equipment is disconnected prior to performing this test to avoid
inadvertently activating it.

COMM

PORT1
PORT2

Performs a loop-back test on the serial ports. If they are functioning, PASS is displayed. If they are
not functioning, FAIL is displayed.

RAM

TEST

Tests the unit’s memory. If it is functioning, PASS is displayed. If it is not functioning, FAIL is
displayed.

KEYPAD

TEST

Tests the unit’s individual keypad buttons by displaying the name of the key pressed. If nothing is
displayed, the key is not functioning.

Press the Menu key to exit the test.

SCANNER

TEST

Displays scanned value with control characters.

A/D sub-menus

RAW

VAL

Displays the live current raw AD count.

ZERO

VAL

Displays the captured AD Zero calibration value.

SPAN

VAL

Displays the captured AD Span calibration value.

mV

VAL

Displays the live current millivolt signal voltage.

EXCVDC

VAL

Displays the current excitation voltage.

LOOP

TEST

Performs a loop test on dig I/O cards.

DIO 1
DIO 2
DIO 3
DIO 4

STATUS

Displays the status of each individual digital I/O port. If set as input, the display shows input stats IN
HI or IN LO. If set as output, pressing Enter toggles the output between HI and LO. OUT HI or OUT
LO.

OUT LO is active.

PORT1
PORT2

TEST

Performs a loopback test on serial port 1 or 2. Connect jumper TX and RX together on port 1 or
port 2 before testing.

Parameter

Choices

Description

Table 3-19.