Introduction

3

1.4

Keypad Functions

Table 1-2. Keypad Functions

Key

Function

POWER

Turns the

Counterpart

unit on/off.

Note

If the PC1 jumper is set to SW, the POWER button must be used to turn the unit on and off.
If the PC jumper is set to ON, the unit will automatically power on when it’s plugged in and
the only way to turn it off is to unplug power.

MENU

SETUP

Enters Menu mode, allowing configuration if the Audit jumper is in the “ON” position. Also used as an escape
key in Menu mode.

ZERO

Sets the current gross weight to zero, provided the amount of weight to be removed or added is within the
specified zero range and the scale is not in motion. The zero band is defaulted to 1.9% of full scale, but can be
configured for up to 100% of full scale.

Note

1.9% is required for legal-for-trade applications.

UNIT

WEIGHT

Used to enter a known unit weight of a part. Up to 10 characters may be entered including zero.

PRINT

Sends “on-demand” serial information out the serial port, provided the conditions for standstill are met.

TARE

Performs one of several predetermined Tare functions dependent on the mode of operation selected in the
TAREFN parameter. To view a stored tare, see Section 1.5.
Also acts as the ENTER key.

B/N

GROSS

NET

Allows the display to change between gross mode and net mode.

SAMPLE

Pieces

Used for computing the unit weight by sampling.
Press the SAMPLE key after placing a sample on the platform or after using the numeric keypad to enter the
sample size.
The default sample size is 10.

UNITS

TOGGLE

Switches the weight display to an alternate unit. The alternate unit is defined in the Setup Menu and could be
kg, g, lb, oz.

Clear key. Used to backspace on entries.

Alpha-Numeric
keypad

Used to enter values directly. Press keys for lower and upper case alpha characters.
See Figure 1-1 on page 4