5.11 Connecting a Barcode Scanner

The Counterpart will accept a barcode scanner connected to the unit. In order to use a scanner, you must set the
specifications of the Counterpart scale to recognize the scanner to the appropriate port and, in some cases, do the
setup on the scanner required by the scanner manufacturer.
The scanner allows non-contact, instantaneous, and accurate input of unit weight, tare weight, and ID code.

QD2100 Barcode Scanner
If you are using the Quickscan QD2100 barcode scanner sold by Rice Lake Weighing Systems, you can set up the
scanner by connecting the scanner (PN121495) to the RS-232 port on the Counterpart CPU board. Plug connector
with three wires into serial port 2 (J4) and plug with one wire into DIGIO (J3). Connections between the barcode
scanner and Counterpart should be wired as shown in Table 5-3.

Table 5-3. Barcode Wiring Connections

Pin out

Wire Color

RX

Green

TX

Red

Ground

Black

DIGIO

5+

The default baud rate is set for 9600 for both Counterpart and the scanner.

To set up barcode scanner parameters:

1. Navigate through the menu Setup >> Config >> Serial.
2. Set up the selected Port, J5 (Port 1) or J4 (Port 2) for the scanner.
3. Follow through and set up the various parameters such as 9600 baud, 8 bits, 1 stop bit, none parity.
4. Headers are set to

ON

under scanner sub-menu when needing to have headers for IDs, tare and unit

weights.

5. If the header is set to

OFF

, the Counterpart assumes that all scanned items are ID codes and part numbers.

Note

ID codes are not functional when scanning ID codes.

Table 5-4. Header Codes for Bar Codes

Header Number

Description

Action

1

Unit Weight

The scanned unit weight value updates the working ID and is also applied.

3

ID Code

The scanned ID code is loaded.

4

Tare

The scanned tare value updates the working ID and is also applied to the scale.

L

Lot Number

The scanned lot number updates the working ID and a Yes/No prompt is shown asking if the
stored ID should also be updated.

M

Part Number

The scanned part number updates the working ID and a Yes/No prompt is shown asking if the
stored ID should also be updated.

Note: Part Number 121495 is supplied with 2 connectors. Plug connector with 3 wires into J4 and set plug. Plug connector with 1 wire into J3.

5.12 USB Keyboard

The USB keyboard requires USB option and setup of parameter.

Keyboard entry of ID/Code information
Function keys 1-5 operate as function keys of counterpart. Function key 11 operates as sample key.