Figure 5-6. batching switch wiring diagram example – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. E - Version 2.5 User Manual

Page 76

Advertising
background image

70

Counterpart Counting Scale Indicator

.

RED

WHITE

BLACK

RED

BLACK

STOP/START MUSHROOM SWITCH

ABORT/RUN/START SWITCH

A
B
O
R
T

S
T
A
R
T

3

4

1

2

NO

NC

NC

NO

NO

J3

+5VDC

GND

DIO1

DIO2

DIO3

DIO4

DIGITAL I/O

1

2

4

5

6

3

CPU BOARD

3

4

1

2

3

4

10

. . . . . .

Figure 5-6. Batching Switch Wiring Diagram Example

To begin a batch process, turn the 3-way switch to START momentarily. If the STOP button is pushed during the
batch process, the process halts and the button locks in the IN position.

The START switch is ignored while the STOP button is locked in the IN position. The STOP button must be turned
counterclockwise to unlock it, then released into the OUT position to enable the 3-way switch.

To restart an interrupted batch from the step where it left off, do the following:

1. Unlock the STOP button (out position).

2. Turn the 3-way switch to START.

To restart an interrupted batch from the first batch step, do the following:

1. Turn 3-way switch to ABORT.

2. Unlock STOP button (out position).

3. Turn the 3-way switch to START.

Note

Use this procedure (or the BATRESET serial command) to initialize the new batch routine following any change
to the setpoint configuration.