3.10 Setpoints – Weigh Mode Parameter Menu

Set up of setpoints is allowed while in the weigh mode.
While setting up setpoints, the Access parameter needs to be set to either On or Off.

• Setting it to

On

allows a setpoint to be viewed and edited if setpoint type is Gross, Net, Piececnt, %Rel, Delay,

or Counter.

• Setting it to

Off

allows a setpoint to be viewed but not edited if the setpoint type is Gross, Net, Piececnt, %Rel,

Delay, or Counter.

• Hide will not show the setpoint.

ID

DISPLAY

TEST

SETUP

AUDIT

CALIBR

SETPTS

BANDVAL

number

If TRIP=

INBAND or

OUTBAND

If TRIP=

HIGHER or

LOWER

HYSTER

number

If PREACT=

ON or

LEARN

PREVAL

number

If KIND=

% RELSP

RELNUM

1-6

PRESTAB

PCOUNT

PREADJ

number

If PREACT

=

LEARN

VALUE

number

GROSS

NET

PIECECNT

%REL

In Weigh Mode

DELAY

COUNTER

VALUE

number

VALUE

number

SAME AS SETPT 1

SETPT 1

SETPT 2 - 6

Figure 3-25. Setpoint Menu in Weigh Mode

Parameters

Choices

Description

SETPT1-6

OFF
GROSS
NET
PIECECNT
%REL
DELAY
WAITSS
COUNTER
INMOTION

Specifies the setpoint kind.
GROSS, NET, PIECECNT, and %REL setpoint kinds can be used as either batch or continuous
setpoints. DELAY, WAITSS, and COUNTER setpoint kinds can only be used in batch
sequences.
The INMOTION setpoint kind can only be used as a continuous setpoint.

Table 3-20. Setpoint Menu Parameters in Weigh Mode

Advertising