5 ids – Rice Lake Counterpart Configurable Counting Indicator - User Manual Rev. E - Version 2.5 User Manual

Page 68

Advertising
background image

62

Counterpart Counting Scale Indicator

Counting Out of a Full Container — See Total Amount Remaining in the Container
To carry out this operation you must know the tare weight ahead of time.

1. Place the full container on the scale. Press the

TARE

key.

2. Remove a 10 piece sample from the container and press the

SAMPLE

key. After the unit weight has been

calculated, return the sample to the container.

3. If you want to see how many are still in the bin, you first have to know the tare weight of the bin or

container. After removing the parts you want to take out of the bin, enter the tare weight of the bin and
press the

TARE

key. The scale will display how many parts were left in the bin. To print a label to put on the

bin showing the total quantity in the bin, press the

PRINT

key.

Negative Counting — Total Removed Displayed at the End
With this procedure you can count accurately out of a full container for kitting or shipping without having to know
the tare weight of the container.

1. Place a full container on the scale and press

TARE

.

2. Remove a 10 piece sample from the container and press

SAMPLE

. After the unit weight has been

calculated, return the sample to the container.

3. Remove the number of pieces you need for kitting or shipping. The amount removed will be displayed. If

you need a label for each kit or container, press the

PRINT

key after removing each batch of pieces.

5.5

IDs

IDs are used to save and recall previously set codes, descriptions, unit weight, and tare preferences. The
Counterpart has the capacity to store up to 150 individual IDs. There are three ways IDs can be entered and set:

1. Normal

2. Through Count Mode

3. Through Revolution

To enter alpha ID characters, double press the numeric keypad to obtain alpha characters.

To store more than 150 IDs, WeighVault is required (see Section 5.6 on page 65).

VALUE

VALUE

VALUE

VALUE

VALUE

QUANTITY

VALUE

CODE

VALUE

DESC

VALUE

PART NUM

LOT

UNIT WT

TARE

UNITS

LOCATION

REG 1

REG 2-150

SAME AS REG 1

G

OZ

OFF

KG

LB

ID

DISPLAY

TEST

SETUP

AUDIT

CALIBR

SETPTS

Figure 5-1. ID Menu

Advertising