Scale Operations

67

5.7

Totalization Counts

Counterpart has a totalization function that allows you to totalize the quantity of several weighings together. This is
especially helpful if putting together parts kits. The ID code is functional with totalization, count or weight.
For full operation of the totalization feature, configure the unit with the following softkeys:

TOTAL+
TOTAL-
Clear Total

To find the total accumulated quantity of similar containers filled with parts, use the totalization procedure detailed
below. Six containers are used in this example; all containers are of the same empty weight.

1. Conduct a sampling process to determine the unit weight of the pieces, or key in a known unit weight or

recall an ID.

2. Enter a known tare weight or place an empty container on the scale to perform tare function. If an ID was

recalled in step 1, its tare value is already loaded.

3. Place container 1 (full of parts) on the scale. The number of pieces in the container is shown in the

PCS

area of the display.

4. Press the

Total +

softkey to store the number of pieces in container 1. The memory (

M

) icon is shown. The

net weight of the items in the containers is stored and the totalization count is incremented. The piece count
value is displayed

.

The total count is shown in place of the unit weight display, and it is labeled as Total

Weight

ttl

.

5. Remove container 1 and place container 2 (full of parts) on the scale.
6. Press the

Total +

softkey. The accumulated total is now equal to container 1 plus container 2. The displayed

total is also updated.

7. Continue with the remainder of the containers in the same totalization method. The total number of parts

stored in all six containers (and the weight of the parts in those containers) is now stored and shown on the
display.

Note

An ID may be loaded while part totalization is being performed, the ID Quantity value is not affected by
the totalizations operations.

If a totalization has been started and the

Code

softkey is pressed — the unit will prompt

Exit Totalization

Mode?

with

Yes

and

No

softkeys. Pressing

Yes

clears the total, exits from totalization mode and brings up

the normal prompt for entering an ID code. If

No

is pressed, the unit does not prompt for an ID Code and

totalization can continue.

The user cannot switch to another scale during totalization. If the

Unit Toggle

key is pressed during

totalization, the message

not allowed — totalizing

will be displayed and the switch will not occur.

The user cannot switch units during totalization. If the

Unit Toggle

key is pressed during totalization, the

message

not allowed - totalizing

will be displayed and the switch will not occur.

During totalization an icon is displayed between the battery icon and the main display area label. The icon
is an uppercase M for memory.

For each totalization done (

Total+

or

Total-

) a count will be incremented. This value can be printed. When

the total value is cleared and totalization mode is exited, the count will be cleared as well.

While in totalization mode, pressing the

Print

key will print the total format —

TOTALFMT

.

When attempting a totalization, a motion check can be performed based upon the setting of the TOTAL
parameter in the Feature/Count menu. If Total is ON and if there is motion, then one more attempt will be
made after two seconds. The default setting is OFF.

To clear the total value, press the

Clear Total

softkey, and it will clear the total value.