Messages and Alerts

SkyView Pilot’s User Guide - Revision S

12-5

Audio Alerts

When connected to an audio panel or intercom, SkyView can generate tones or voice alerts for
various conditions.

Inhibited Alerts

Audio alerts that occur within 5 seconds of SkyView initially powering on are inhibited to reduce
transient nuisance alerts that may occur as SkyView comes online.

Engine Alerts can be optionally configured to be inhibited before engine start or 5 minutes,
whichever comes first. See the SkyView System Installation Guide for details.

Messages, Alerts, and Audio Alert Details

Spoken Alert (if

configured)

Message Displayed

in Message

Window

Notification

Area Alert

(severity)

Description

“Warning”

ADAHRS FAIL

ADAHRS failure

“ADAHRS Cross Check

Error”

ADAHRS CROSS CHK

ERROR

Displayed after an ADAHRS cross-

check error was announced in a

multi-ADAHRS systems, but the

pilot did not disable one of the

disagreeing ADAHRS.

“Warning”

ADAHRS INTERNAL

ERROR

SkyView has detected a problem

with the ADAHRS module. Contact

Dynon for assistance

“Warning”

EMS FAIL

Engine monitor failure

“Engine Monitor”

“Oil Pressure”

“Fuel Pressure”

“Fuel Flow”

“Fuel Quantity”

“Electrical Current”

“Voltage”

“Exhaust Gas

Temperature”

“Cylinder Head

Temperature”

“Engine Speed”

<Engine Parameter>

HIGH or LOW

Engine Parameter High or Low.

“High” or “Low” is not displayed

for all parameters.

Engine Alerts can be optionally

configured to be inhibited before

engine start or 5 minutes,

whichever comes first. See the

SkyView System Installation Guide

for details.

“Warning”

ADAHRS CAL

CORRUPT

Contact Dynon for assistance

Advertising