Sv-gps-250 quick specifications -4, Sv-bat-320 quick specifications -4 – Dynon Avionics SkyView Pilots Users Guide User Manual

Page 232

Advertising
background image

Appendix A: SkyView System Specifications

13-4

SkyView Pilot’s User Guide - Revision S

Sensor Inputs

(2) Voltmeters (0 to 30 volts DC)
(11) General Purpose
(3) General Purpose Enhanced
(2) Fuel Flow
(1) Amps (differential)
(1) Manifold Pressure
(2) General Purpose Thermocouple (SV-EMS-220 only)
(Left and Right) RPM
(Left and Right) RPM
(6) CHT
(6) EGT
(1) CAN Bus for Rotax 912 iS (SV-EMS-221 only)

Other Inputs, Outputs,

and Communication

Ports

(1) +12 volt DC auxiliary sensor power output
(1) +5 volt DC auxiliary (fuse limited at 500 mA) sensor
power output
(1) SkyView Network Port
(1) External Alarm Light Output

SV-GPS-250 Quick Specifications

Mechanical

2.19” wide x 0.75” tall x 3.44” deep (56 x 19 x 88 mm)
6.7 oz. (0.19 kg)

Operating Temperature

-40° to 140° F (-40° to +60° C)

Connections

(1) Power wire
(1) Ground wire
(1) Serial TX (NMEA format; 5 Hz update rate)
(1) Serial RX

SV-BAT-320 Quick Specifications

Mechanical

3.30” wide x 2.10” tall x 3.90” deep (162 x 28 x 76 mm)
9.6 oz. (0.27 kg)

Operating Temperature

Charge:

32° to 113° F (0° to +45° C)

Discharge:

-4° to 140° F (-20° to +60° C)

Connections

(1) 3 pin power

Advertising