Dynon Avionics SkyView Pilots Users Guide User Manual

Page 38

Advertising
background image

SV-D700, SV-D1000 and SV-D1000T Operation

3-12

SkyView Pilot’s User Guide - Revision S

o The self-test routine has not discovered abnormal behavior. Backup battery self-

tests are performed automatically every time master power is removed on the
ground (after a flight, for example) while the 30-second “power lost” timer is
counting down.

Needs test:

Figure 7 - Backup Battery Test Needed

SkyView has determined that the backup battery should be tested using the manually-
actuated Backup Battery Test. This can be because:

o It has been one year since the last full Backup Battery Test. See the SkyView

System Installation Guide for instructions on how to perform this test.

o The 30 second automatic battery self-check that is performed when master

power is removed during a normal shutdown did not complete properly at least
3 consecutive times. Perform the Backup Battery Test per the SkyView System
Installation Guide.

Fault/test Failed

Figure 8 - Backup Battery Test Failed

A fault has been detected because of one of the following conditions:

o The battery is no longer connected.
o A battery test has failed. The battery may need to be replaced. Contact Dynon

Technical Support for more information.

Advertising