EVENT SETTINGS
SM Event Settings

[ If "Zone volume adjustment (Pulse)" is selected for "Function" ]

(3) Contents (left side)

Select the output zone pattern of which sound volume is to be adjusted.
If the output zone is set to "End," it is not possible to set "Volume level increment/decrement" (next item).

End (default), Set output zone pattern

Available Settings

(4) Contents (right side)

Adjust the amount to increase or decrease the sound volume level of the output zone pattern.

0 dB (default), –10 to +10 dB (in 1-dB steps)

Available Settings

[ If "Zone volume attenuate (Level)" is selected for "Function" ]

(3) Contents (left side)

Select the output zone pattern of which sound volume is to be attenuated.
If the output zone is set to "End," it is not possible to set "Attenuation" (next item).

End (default), Set output zone pattern

Available Settings

(4) Contents (right side)

Select the attenuation level.

–1 dB, –2 dB, –3 dB, –6 dB, –10 dB, –20 dB, (default), –40 dB, –infinity dB

Available Settings

[ If "Emergency broadcast pattern start" is selected for "Function" ]

(3) Contents (left side)

Select the emergency broadcast pattern to be activated by the control input.
Set the emergency broadcast pattern using

"Pattern settings

Emergency broadcast pattern settings"

(p. 83)

.

None (default), Set emergency broadcast pattern

Available Settings

[ If "Emergency broadcast pattern stop" is selected for "Function" ]

(3) Contents (left side)

Select the emergency broadcast pattern to be stopped by the control input.
Set the emergency broadcast pattern using

"Pattern settings

Emergency broadcast pattern settings"

(p. 83)

.

Set emergency broadcast pattern (default: Pattern 1)

Available Settings

[ If "Emergency sequence stop" is selected for "Function" ]

(3) Contents (left side)

Select the emergency sequence to be stopped by the control input.
Set the emergency sequence using

"Pattern settings

Emergency sequence settings" (p. 82)

.

Set emergency sequence (default: Sequence 1)

Available Settings