• Time out (min)

The time-out period can be set when the "Talk" key operation method has been set to "Lock" mode.
Select an appropriate time-out period after which Remote Microphone announcements are automatically
terminated if the user fails to turn off the microphone power.

Continuous (default), 1 – 20 (minutes)

Available Settings

• Start chime

Select the type of chime tone to be sounded before Remote Microphone announcements are made.

None (default), 1 (Chime 1), 2 (Chime 2), 3 (Chime 3), 4 (Chime 4)
Tip: The system chime is set to:

1 (ascending 4-note tone), 2 (descending 4-note tone), 3 (2-tone chime),
4 (gong)

Available Settings

• End chime

Select the type of chime tone to be sounded after Remote Microphone announcements have been
completed.

None (default), 1 (Chime 1), 2 (Chime 2), 3 (Chime 3), 4 (Chime 4)
Tip: The system chime is set to:

1 (ascending 4-note tone), 2 (descending 4-note tone), 3 (2-tone chime),
4 (gong)

Available Settings

• Chime volume (dB)

Select the volume of the chime broadcast by the Remote Microphone.

0 to –20 dB (default: –6 dB), in 2-dB steps

Available Settings

SYSTEM SETTINGS

RM-200S, RM-200SA

(2) Function settings

• Name

Enter a name of the RM-200S or RM-200SA.

• Type

Select the type of broadcast.

General (default), Emergency/General

Available Settings

• PTT or Lock

Select the RM-200S's or RM-200SA's "Talk key" operation method.

PTT (default), Lock

Available Settings

[PTT and Lock]

Two different methods are available for Talk key operation: Press-to-Talk (PTT) and Lock modes.

PTT:

Enables microphone announcements to be made while the Talk key is being pressed.

Lock:

Enables microphone announcements by pressing the Talk key once and terminates by
pressing it again.

Up to 32 alphanumeric characters. (Default name is the same as that in the
Name (1) on the previous page.

Available Settings

Note: The type for the RM-200S is fixed to "General."