Toa SX-2000 Series User Manual

Page 60

Advertising
background image

60

SYSTEM SETTINGS

RM-200S, RM-200SA

• Wait time (sec)

Set the time required to start broadcast* after the talk key on the remote microphone has been pressed.
Select the time according to the start-up time of connected power amplifiers or line selection relays.

* When "None" is selected in the Start chime setting, wait time means time duration before the

microphone announcement starts, while when the value other than "None" is selected, it means the
time duration before the chime sounds.

0 (default), 0.5, 1.0, 1.5, 2.0, 3.0, 4.0

Available Settings

• RM-210

Select the number of RM-210 Remote Microphone Expansion units.

0 (default), 1 – 4

Available Settings

(3) Key names

Enter each name of the Covered key and function keys on the RM-200S's or RM-200SA's top panel.

RM-200SA

RM-200S/200SA top

1

EMG

SYS1

SYS2
SYS3

Function keys

Function keys

Covered key

10

Up to 32 alphanumeric characters. (default: EMGKEY for the Covered key,
SYSKEY 1 – 3 for the Function keys (on the left), and KEY 1 – 10 for the Function
keys (on the right))

Available Settings

(4) RM-210 selection

This setting is valid when the "RM-210" has been set to 1 to 4 in the Function settings (2).
Click on the box, or press the right or left arrow button to select the target RM-210.

(5) Function key names

Enter each name of the function keys on the RM-210's top panel.

RM-210 top

Function keys

11

20

(6) Copy and Paste buttons

Pressing the [Copy] button copies all of the on-screen settings except the names preset by default.
Pressing the [Paste] button pastes the copied parameters in the same setting screen of other RM-200S or
RM-200SA selected by Name (1).

Up to 32 alphanumeric characters. (default: KEY 11 – 50)

Available Settings

(7) Back button

Returns to the previous screen.

Advertising