PATTERN SETTINGS

Failure Output Pattern Settings

(6) Copy and Paste buttons

Pressing the [Copy] button copies all of the on-screen settings except the name preset by default.
Pressing the [Paste] button pastes the copied parameters in the same setting screen of other failure output
pattern selected by Number (1).

(5) Failure status output

Set the control output pattern to be output when the set failure output pattern has occurred.
This setting item is valid when at least one surveillance target point is selected in the item (3).

None (default), Set control output patterns

Available Settings

(4) External failure input

This function is available when the

"External failure input" (p. 97)

is set to the control input terminals of the

SX-2000SM, SX-2100AI, SX-2000AO, SX-2100AO, and SX-2000CI.

Note
Use the Event of each unit in the "Event Settings" to set the function to the control input terminals.
For details, refer to

pages 101 – 119

.

None (default), External failure input terminals set in the "Event Settings."

Available Settings

(2) Name

Enter the names of the failure output pattern.

(3) Failure detection units or surveillance target points settings

Select the units or surveillance target points as factors to activate failure
output patterns.
Tip
For quick selection of multiple cells, refer to

p. 75 "Selecting multiple

cells."

Colored (Selected), Colorless (Not selected, default)

Available Settings

Up to 32 alphanumeric characters. (default: Failure output pattern 1 – 256)

Available Settings

[When selected]

(1) Number

Click on the box or press the arrow button to select the failure output pattern number.

1 to 256 (default: 1)

Available Settings

any one of the units within the system.
Determine the method to activate the failure output patterns using the

"Event Settings (p. 87)."

Each setting button on the screen represents the surveillance points as shown below.

DC POWER: DC power of the SX-2000SM, SX-2000AI, SX-2100AI, SX-2000AO, SX-2100AO, SX-2000CI,

or SX-2000CO

DC FUSE*:

Fuse inside the amplifier connected to the SX-2100AO

DS LINK:

DS link of the SX-2000SM and SX-2100AO

SX LINK:

SX link of the SX-2000SM, SX-2000AI, SX-2100AI, SX-2000AO, and SX-2100AO

RM LINK:

RM link of the remote microphone connected to the SX-2000AI or SX-2100AI

* DC FUSE setting button becomes active when the "Amplifier" checkbox is marked in the

"Surveillance

Settings (p. 69)."