EVENT SETTINGS

Assignable Functions and Explanations

• General broadcast:

Activates general-purpose pattern broadcast using the key.
(Refer to

p. 90

.)

• General broadcast (Level):

Activates general pattern broadcasts using the control input (Level).

(Refer to

p. 90

.)

• General broadcast (Pulse):

Activates general pattern broadcasts using the control input (Pulse).
(Refer to

p. 91

.)

• BGM pattern change/end:

Activates or ends BGM pattern broadcast using the key or control
input. (Refer to

p. 92

.)

• Zone volume adjustment (Pulse):

Adjusts the volume level of the zone output pattern using the key or
control input (Pulse). (Refer to

p. 93

.)

• Zone volume attenuation (Level):

Decreases volume level of the zone output pattern using the key or
control input (Level). (Refer to

p. 93

.)

• Time adjustment:

Zero-adjusts the SX-2000SM's internal clock. (Refer to

p. 93

.)

• Emergency broadcast pattern start:

Activates the emergency broadcast pattern using the key or control
input. (Refer to

p. 94

.)

• Emergency broadcast pattern stop:

Stops the activated emergency broadcast pattern using the key or
control input. (Refer to

p. 94

.)

• Emergency sequence stop:

Stops the activated all emergency broadcast patterns which include

the designated emergency sequence using the key or control input.
(Refer to

p. 94

.)

• Emergency sequence phase shift:

Shifts the phase in progress to the next phase in the emergency
broadcast pattern's sequence using the key or control input.
(Refer to

p. 94

.)

• Emergency reset:

Terminates the emergency broadcast state using the key or control
input, and returns the system to the normal state. (Refer to

p. 94

.)

• Failure output receipt:

Receives the activated failure output pattern using the key or control
input. When this function is assigned to the control input, any activated
failure pattern in the system can be acknowledged by the control
input, while when assigned to the remote microphone's key, only the
activated specific failure pattern can be acknowledged by the key.
(See the separate Operating Instructions, "Operation.")

• Failure output reset:

Resets all fault state in the system using the key or control input.
(See the separate Operating Instructions, "Operation.")

• External failure input:

Accepts an external failure state. (Refer to

p. 97

.)

• RM broadcast status:

Displays the current broadcast status of other remote microphone(s)
on the remote microphone's function key. (Refer to

p. 98

.)

• General EV broadcast:

Calls up the EV message from the remote microphone's function key
for broadcast. (Refer to

p. 99

.)

• Channel ON/OFF:

Turns the channel ON or OFF.

• Zone selection (Pattern):

Selects the Remote Microphone announcement zones using the
patterns. (See the separate Operating Instructions, "Operation.")

• Zone selection (Individual):

Selects each SX-2000AO's or SX-2100AO's channel through which
Remote Microphone announcements are output.
(See the separate Operating Instructions, "Operation.")

• Zone selection clear:

Resets zones being selected by the Remote Microphone.

• Lamp test:

Performs the lamp test of the RM-200SF's of RM-200SA's indicators.