Toa SX-2000 Series User Manual

Page 131

Advertising
background image

131

UTILITY

System Status Display Confirmation

[Button indication priorities when multiple statuses occur simultaneously]

(High) Emergency cutoff

CPU off
CF card error, Maintenance
Error

(Low)

Normal, Power failure (N), Emergency, Power failure (E), Initialization

[Button display priorities when multiple statuses simultaneously occur]

Error > Difference > Correct

2. AI

Displays SX-2000AI or SX-2100AI system status.
A number represents the unit number of the SX-2000AI or SX-2100AI that has been set for connection.
Clicking the button displays the detailed information screen (AI unit screen).
(Refer to

p. 136 "AI unit screen"

)

On-button indication

System status

(Blank)

No connection setting.

Correct

The SX-2000AI or SX-2100AI is operating correctly.
(Preprogrammed units match actually connected units.)

Error

The SX-2000AI, SX-2100AI, RM-200S, RM-200SA or RM-210 has failed.

Difference

Preprogrammed units do not match actually connected units.

On-button indication

System status

CF card error

CF card irregularities detected:
• CF card not inserted.
• Cannot read the CF card since the SX-2000SM's DIP switch 2 is set to ON.
• No setting data.
• Cannot read setting data.
• No EV message data.
• EV message data irregularities detected.
• Insufficient space available on CF card.
• CF card has failed.

Maintenance

Operating in maintenance mode.
• The SX-2000SM's DIP switch 2 is set to ON.
• CF card not inserted.

Initialization

Initialization in progress.

CPU off

The system is in the CPU off state.
Since the RM-200S, RM-200SA, RM-210, SX-2000CI and SX-2000CO are reset
in the CPU off state, they are disconnected.

Emergency cutoff

One of the SX-2000AO units is in the emergency mode that cuts off 24V DC to
allow emergency broadcasts to go through.

Error

The SX-2000SM has failed.

Advertising