Control input/output status display screen – Toa SX-2000 Series User Manual

Page 153

Advertising
background image

153

UTILITY

Control Input and Output Status Confirmation

13.5.1. Control input/output status display screen

1

2

3

4

1. SM control input/output terminals

Display the SX-2000SM's control input and output statuses.

2. AI control input/output terminals

Display the SX-2100AI's control input and output statuses.
(The SX-2000AI's status is not displayed, since it has no control input and output terminals.)

3. AO control input /output terminals

Display the control input and output statuses of the SX-2000AO or SX-2100AO.

4. CI/CO control input/output terminals

Display the control input and output statuses of the SX-2000CI and SX-2000CO.
The status of these units is not displayed if the SX-2000CI or SX-2000CO is not connected to the
SX-2000AO or SX-2100AO.

If the control input (CIN) and control output (COUT) are turned ON, a mark is placed in their
corresponding boxes.

When the control input closes ("makes"), the corresponding boxes are marked by circle (

).

(green):

The control input is closed. If the control input is closed by pulse signal, the color is
displayed only while an event remains active.

(orange): The control input terminal to which the external failure input has been assigned is closed.

This indicates that the external connected device has failed.

(gray):

The control input terminal to which no functions have been assigned is closed.

When the control output turns on, the

mark is placed in the corresponding boxes.

(blue):

The control output is turned on.

(red):

The control output corresponding to the zone for which attenuators were set to be "used"
in emergency broadcasts is turned on.