Before you begin, Programming information sheet, Getting started – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 10: Introduction, 1 before you begin, 2 getting started

Advertising
background image

XR500 Series Canadian Programming Guide

Digital Monitoring Products

1

INTRODUCTION

Introduction

1.1

Before you Begin

This guide provides programming information for the DMP XR500, XR500N, and XR500E Command

Processor™ Panel. After this Introduction, the remaining sections describe the functions of each

programming menu item along with the available options. Before starting to program, we recommend

that you read through the contents of this guide. The information contained here allows you to quickly

learn the programming options and operational capabilities of the XR500, XR500N, and XR500E panels.
In addition to this guide, you should also read and be familiar with the following XR500 Series Canadian

documents:

• XR500 Series Canadian Installation Guide (LT-0681CAN)
• XR500 Series Canadian Programming Sheet (LT-0678CAN)
• XR100/XR500 Canadian Security Command

®

User’s Guide (LT-0683CAN)

Internal Programmer
The panel contains all of its programming information in an on-board processor and does not require an

external programmer. You can perform all programming tasks through a 32-character DMP alphanumeric

keypad set to address one.

Programming Information Sheet
Included with each panel are the Programming Information Sheets. These list the various programming

prompts and available options for programming the panel. Before starting to program, we recommend you

completely fill out each sheet with the programming options you intend to enter into the panel.

Having completed programming sheets available before entering data helps prevent errors and can shorten

the time you spend programming. Completed sheets also provide you with an accurate panel program

record you can keep on file for future system service or expansion. The remainder of this Introduction

provides instructions for starting and ending a programming session using the alphanumeric keypad.

1.2

Getting Started

Ground Yourself Before Handling the Panel! Touch any grounded metal, such as the enclosure, before

touching the panel to discharge static.
Remove All Power From the Panel! Remove all AC and Battery power from the panel before installing or

connecting any modules, cards, or wires to the panel.
Before starting to program the XR500 Series Canadian panel, make sure the panel is properly grounded and

AC and battery power is applied to the appropriate panel terminals. All wiring connections and grounding

instructions are detailed in the XR500 Series Canadian Installation Guide (LT-0681CAN).

Program from any Keypad Address or Wireless Keypad
Program from any Keypad Address or Wireless Keypad
You can program the XR500 panel from any 32-character wireless keypad or hardwired keypad connected

to the panel’s keypad data bus. See the XR500 Installation Guide for keypad addressing and installation

information for hardwired keypads.
Wireless Keypads can be used for panel programming after being programmed in the panel manually or by

using the Wireless Keypad Association operation.

To enable association operation in the keypad, access the Installer Options Menu (3577 (INST)) and

select RF Survey. The keypad logo LEDs turn on Red until association is successful.
To enable association operation in the XR500 panel, reset the panel 3 times within 12 seconds. Allow

the panel’s keypad bus Transmit/Receive LEDs to turn back on between each reset.
For 60 seconds the panel listens for wireless keypads that are in the Installer Options Menu and have

not been programmed, or associated into another panel. Those keypads are assigned to the first

open device position automatically based upon

the order in which they are detected. The

keypad logo turns Green to indicate it has been

associated with the panel. See the 9000 Series

Wireless Keypad Installation Guide (LT-1107) for

additional information.

Accessing the Programmer

1. Momentarily place the Reset jumper over both

of the J16 pins to reset the panel.

2. Enter the code 6653 (PROG) and press

COMMAND.

3. The keypad displays:

PROGRAMMER.

Figure 1: XR500 Series Canadian Panel Showing Reset

J6

Interface

Card

Expansion

Connector

To enable Wireless Keypad

Association operation:

Reset panel 3 times within

12 seconds.
To access the programmer:

Momentarily place the

Reset jumper over both of

the J16 pins to reset the

panel.

AC

1

2

3

4

5

6

7

8

10

11 12 13 14

15 16 17 18 19

9

20

21 22 23 24 25 26 27 28

+B

BELL GND

SMK GND

RED YEL GRN BLK

Z1

Z2 Z3

Z4 Z5

Z6 Z7

Z8 Z9+ Z9– Z10+ Z10–

AC

–B

GND

GND

GND

GND

K6

K7

Output 1

Output 2

J3

Phone Line

J10

J22

LX-Bus

Battery

Start

J23

J21

RS-232

Power

LED

J8

PROG

J4

Tamper

J16

Reset

Out1

Out2

Outputs 3-6

J11

3

4

5

6

J2

J1

Ethernet

R

L

X

OVC

Link LED

Activity LED