XR500 Series Canadian Programming Guide

Digital Monitoring Products

61

STOP

SET LOCKOUT CODE

Stop

20.1

STOP

Stop

Save Programming

WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN
AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE
PROGRAMMING CHANGES.

At the STOP prompt, pressing any Select key allows you to exit the Programmer

function of the panel. When selected, the panel performs an internal reset and

exits the programmer.
The STOP routine causes the following conditions to occur:

• All 1100 Series DMP Wireless transmitters are reset to NORMAL
• The panel Status List is cleared

During the reset, all keypad displays are momentarily blank for two seconds. After

the reset, the programming function terminates and the keypads return to the status

list display.
The STOP prompt does not disarm the system. Any new areas or zones that were

added during programming are not armed until the system is disarmed and armed

again.
Missing LX-Bus™ Modules Displayed

The Programmer includes a feature following the STOP routine that displays the

name of any programmed LX-Bus module not currently connected to the panel. For

example, if you had enabled any LX-Bus options and not yet installed a 481 LX-Bus

Expansion Card, after the STOP routine the panel displays NO LXBUS CARD. This is a

helpful reminder to install the card. This feature can also be a troubleshooting tool

to indicate a problem if you installed the card and this message still displays. The

following list shows the different messages and their associated LX-Bus cards.

Keypad Display

Missing Card

NO LXBUS CARD

481 LX-Bus™ Expansion Card

NO PRINTER CARD

462P Printer Interface Card

NO HOST CARD

462N Network Interface Card

(with NETWORK communication selected)

The above messages clear automatically from the keypad after a few moments.
Power Up

When the XR500 Series Canadian panel is powered up after an AC power failure,

any zone transitions are not recognized for 120 seconds. Normal zone processing

resumes at the end of the 120 seconds.

Set Lockout Code

21.1

SET LOCKOUT CODE

Set Lockout Code

Pressing COMMAND at the STOP prompt displays SET LOCKOUT CODE. This allows

you to program a code that is then required to gain access to the panel internal

Programmer through the keypad. You can change this code at any time to any

combination of numbers from three to five digits long. You do not need to enter

leading zeros when using the lockout code. Initializing the panel does not clear a

Lockout Code. Lockout Codes can be changed through Remote Link.
Once you have changed the code, it is important to write it down somewhere and

store it in a safe place. Lost Lockout Codes require the panel to be sent back to

DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout

Code command.
Lockout Code restriction

Do not set a Lockout Code higher than 65535.