Zone information, 1  zone information, 2  zone number – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 57: 3  zone name, Zone number, Zone name

Advertising
background image

Digital Monitoring Products

XR500 Series Canadian Programming Guide

48

AREA INFORMATION
18.16

ARMED OUTPUT: 0

Armed Output Number

Enter the output to turn on when this area is armed. If an exit delay is used for this

area, the Armed Output turns on at the start of the exit delay. The output is turned

off when this area is disarmed. The output cannot be turned on from the User Menu

Outputs On/Off option.

18.17

LATE OUTPUT:

0

Late Output Number

Enter the output to turn on when this area is not armed by its scheduled time and

Area Late or Closing Time displays at a keypad and the keypad buzzer is on. The

output is turned off when the keypad buzzer is silenced by pressing any key. Default

is 0 (zero).

18.18

LATE/ARM DLY: 60

Late Arm Delay

Enter 4 to 250 minutes to delay before automatic re-arming occurs after the area

becomes disarmed outside of schedules. See Closing Check. Default is 60 minutes.
Note: The Late Arm Delay can be superseded by the Re Arm Delay setting of the

User Profile assigned to the user who disarmed the area. Refer to the Re Arm Delay

section in the XR500 Series Canadian User’s Guide (LT-0683CAN).

18.19

BANK/SAF NO YES

Bank Safe & Vault (XR500N/XR500E only)

NO disables the Bank Safe & Vault feature for this area. When selected as YES,

schedules set for this area and the time of day cannot be changed while the area is

armed.
Program schedules before arming: A Bank Safe & Vault area can only be disarmed

during scheduled times. If the area becomes armed before programming a schedule,

the panel must be reset before the area can be disarmed from a keypad or the

Bank

Safe & Vault option in Area Information must be set to NO.
Zones assigned to Bank Safe & Vault areas cannot be bypassed or force armed. Do

not assign Bank Safe & Vault area to an Arming zone. Arming zones can disarm Bank

Safe & Vault areas outside of a schedule.

18.20

COMMON NO YES

Common Area

Select

YES to enable this area to operate as a common area. This area is armed

when the last area in the system is armed and is disarmed when the first area in the

system is disarmed. You can have multiple common areas in each system. For the

common area to work properly, do not assign the common area to any user code.

When a user code can arm and disarm the common area from a keypad at any time,

the common area does not function as a common area.

18.21

ARM FIRST NO YES

Arm First Area

Select

YES to enable this area to operate as an Arm First area. This area is

automatically armed when any non-Arm First area assigned to the same keypad is

armed but does not disarm when other areas become disarmed. Assign areas to

keypads using the Display Areas option in Device Setup programming. You can have

multiple Arm First areas in a system and divide them among keypads if needed. If

an Arm First area has faulted zones that cannot be bypassed, arming stops and the

areas are not armed. Correct the problem with the Arm First area and then begin

the arming process again. Default value is

NO.

Note: The Arm First automatic arming only occurs when arming from a keypad.

Arming from a zone, schedule, or remotely is not affected and Arm First areas do not

automatically arm.

18.22

TWO MAN NO YES

Two Man Rule (XR500N/XR500E only)

Select YES to require two user code entries to disarm and/or allow door access to

this area. When a user presents a code to a keypad or reader requesting a door

access or disarm, 2ND CODE displays and requires the entry of a different user code

with at least the same authority. The second user code must be entered within 30

seconds.
NO disables the Two Man Rule for this area.

Advertising