Appendix, 1 false alarm reduction, System recently armed report – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 71: 2 diagnostics function, False alarm reduction, Diagnostics function, Feature upgrade

Advertising
background image

Digital Monitoring Products

XR500 Series Canadian Programming Guide

62

FEATURE UPGRADE

Feature Upgrade

22.1

FEATURE UPGRADE

Feature Upgrade

In the Programming Menu, pressing COMMAND at the SET LOCKOUT CODE prompt

displays FEATURE UPGRADE. This allows you to enable additional features in the

panel. Press any top row Select key to display the first available feature. ENABLED

or DISABLED displays indicating whether this feature is currently used in this panel.

Press the COMMAND key to display additional feature(s).

ENTER KEY
-

To enable a feature, press any top row Select key anywhere in the features list to

display the ENTER KEY prompt.
Enter the factory-supplied feature key for the specific panel and press the COMMAND

key. The feature specific to the key displays as ENABLED.
Note: XR500 Series version 106 or higher panels require a six (6) character feature

key. Version 105 panels require a 16-character feature key.
If the feature key entered is not accepted, the ENTER KEY prompt displays again.

Re-enter the feature key and press the COMMAND key.

22.1.1

ENCRYPTION
DISABLED

Encryption

Enable this feature to provide 128 bit AES data encryption. This feature upgrade

can only be enabled on an XR500N panel version 105 or higher. For installations

where an XR500 panel is installed, it is recommended the XR500 be replaced with an

XR500E panel.
To complete encryption installation, access System Status in the User Menu to verify

the encryption status (ON or OFF). If the status displays OFF, it indicates that the

Passphrase has not been entered and data transmissions are not encrypted. See

Network Options to set up a Passphrase.

22.1.2

ALL NO YES OPTN
DISABLED

All No Yes Option

This feature offers the ability to disable the ALL NO YES option at arming or

disarming. When this feature is enabled, the ALL NO YES option does not display

at any system keypad during arming or disarming. Each area assigned to the user

profile is chosen to be armed or disarmed independently.

22.1.3

SVC USER AUTH
DISABLED

Service User Authentication

This feature offers the ability to authenticate service personnel before allowing

access to panel programming or performing any user operations. When this feature

is enabled and a valid Service User code is entered for system operation or 6653 is

entered for programming, the Service Code entry option displays.
When the service person enters the Service Code, the panel authenticates the code

with the Service Code preprogrammed in the SCS-1R receiver, and access to panel

programming or the User Menu is granted. The Service Code can be used for system

operation for 30 minutes before authenticating again. If the code entered is not

validated, access to programming or the User Menu using the Service User code is

denied.
Note: The Service User code is user number zero (0) and can only be created in the

panel remotely. The SCS-1R receiver must have firmware version 902 or higher to

authenticate service personnel.

Purchasing Feature Upgrades
To purchase a feature upgrade, you may contact DMP Customer Service with the

feature you would like to enable and the panel serial number. The serial number(s)

should be sent in writing via e-mail or fax. A separate feature key is issued for each

panel. The feature key only enables the requested feature on the specified panel.
The panel serial number can be located several different ways:

• Printed on a label located on the right side of the XR500 PCB.

• Using panel diagnostics. See the Appendix.

• Using Remote Link™ (version 1.18 or greater). See the Remote Link User’s

Guide (LT-0565).

— Initial Panel Connection screen

— System Information screen.

Advertising