OUTPUT INFORMATION

Output Information

12.1

OUTPUT INFO

Output Information

This section allows you to program wireless outputs and name wired outputs.

12.2

OUTPUT NO. X X X

Output Number

Enter an output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999.
In order for wireless output troubles to display at a keypad, the keypad address must

be specified at the Auxiliary 1 Zones prompt in the Status List programming.

12.3

OUTPUT NAME

Output Name

This section allows you to define a 32 character alphanumeric name for any output

numbers. The name can display on the keypad when a user performs the browser

feature at Outputs On/Off. See the XR100/XR500 User’s Guide (LT-0683CAN)

Appendix for browser operation.

12.4

Output Real-Time Status

Selecting YES allows Real-Time Status reports, such as Output ON, OFF, PULSE, or

TEMPORAL to be sent using PC Log reports. Selecting NO disables Real-Time Status

for this output device. Default is NO.

12.5

SERIAL#: XXXXXXXX

Serial Number

This option and the next option only display when the output number entered is for

a wireless output. Enter the eight-digit serial number found on the wireless device.

ALREADY IN USE

OUTPUT NO: XXX

This message displays when the serial number is already programmed for another

output. The programmed output number displays.

12.6

SUPRVSN TIME: 240

Supervision Time

Press any top row key to select the supervision time required for the wireless

output. Press COMMAND to accept the default time. Default is 240 minutes.
Note: Refer to the Wireless Check-in and Supervision Time Definitions section of the

Appendix for supervision information.

SELECT MINUTES:

0 3 60 240

Press the Select key under the required number of minutes. The wireless output

must check in at least once during this time or a missing condition is indicated for

that output. Zero (0) indicates an unsupervised transmitter.

The 3 minute supervision time is only available if using an 1135 Wireless Siren.

Note: When the panel is reset, a receiver is installed or powered down and powered

up, or programming is complete, the supervision timer restarts for all wireless

outputs.

12.7

Trip with Panel Bell Option

This option displays when the wireless device is an 1135 wireless siren. Select YES to

have the 1135 wireless siren follow the panel’s bell output cadence for the zone type

and bell cutoff time up to 15 minutes. Default is YES.

OUTPUT REAL-TIME

STATUS NO YES

TRIP WITH PANEL

BELL

NO YES