3 pc modem, Pc modem – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 32

Advertising
background image

XR500 Series Canadian Programming Guide

Digital Monitoring Products

23

REMOTE OPTIONS

7.6

PC Modem

YES allows the panel to answer the telco link and connect with Remote Link through

the PC Modem at 2400 baud. NO disables PC Modem communication.

7.7

ALR RCVR NO YES

Alarm Receiver Authorization

Select YES to enable remote commands and programming to be accepted from the alarm

SCS-1R Receiver. The Remote Key option can also be required.
With YES selected, the panel requests the receiver key during its first communication

with the first SCS-1R Receiver. The panel retains this alarm receiver key in memory and

allows remote commands to be accepted from the alarm receiver. If an alarm occurs

during a remote connect, the alarm report is immediately sent to this receiver only.
When NO is selected, remote commands and programming are not accepted from the

alarm SCS-1R Receiver.

7.8

SVC RCVR NO YES

Service Receiver Authorization

YES enables remote commands and programming to be accepted from a secondary

service receiver other than the alarm SCS-1R Receiver. The Remote Key option can also

be required.
With YES selected, the panel requests the service receiver key the first time it is

contacted by the service receiver. The panel retains this service receiver key in memory

and accepts remote commands from the service receiver.
If an alarm occurs during a remote connect, the panel disconnects from the service

receiver and calls the alarm receiver. Alarm reports are only sent to the alarm receiver.

It is important that the alarm receiver key and the service receiver key programmed at

the central station are NOT the same so the panel can determine the difference between

receivers.
When NO is selected remote commands and programming are not accepted from a

secondary service receiver.
This option must be YES to allow programming from a directly connected computer or an
iCOM/iCOM-E.

7.9

Manufacturer Authorization

Select YES to allow DMP Technical Support technicians to access the panel during

system service or troubleshooting. This authorization automatically expires within

one hour.
DMP remote service is provided on a read only basis: DMP technicians can look

at the system programming and make suggestions only. Alterations can only be

accomplished by installing company service personnel.

7.10

Allow Network Remote

This option displays only if the panel has network capability. YES allows remote

programming over the network. Changing this prompt does not change any other

network programming prompts. Default is YES.

7.10.1

NETWORK PROG

Network Programming Port

PORT:

2001

Enter the programming port number. The programming port identifies the port used

to communicate messages from the panel. The default Programming Port setting is

2001.

7.10.2

Encrypt Network Remote

YES encrypts data sent over network. Default is NO.

7.11

Allow Cellular Remote

YES allows remote programming using cellular connection. Default is YES.

7.11.1

First GPRS APN

Enter the first APN (Access Point Name). This allows an access point for cellular

communication and is used to connect to a DNS network. The APN may contain two

lines of 16 characters to equal 32 characters. Default is set to NMRX.CA.APN.

Second GPRS APN

Enter the second APN (Access Point Name). This works as a backup in case the first

APN fails. The APN may contain two lines of 16 characters to equal 32 character

Default is set to INTERNET.COM.

PC MODEM NO YES

MANUFACTURER

AUTH?

NO YES

ALLOW NETWORK

REMOTE? NO

YES

NMRX.CA.APN
-

FIRST GPRS APN:

INTERNET.COM
-

SECOND GPRS APN:

ENCRYPT NETWORK

REMOTE?

NO YES

ALLOW CELL

REMOTE? NO

YES

Advertising