Armed short, Armed open, Disarmed short – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 81: Disarmed open, Fa series w ireless, Dmp w ireless, Fire bell, Area, Type, Xr500 series lx-bus zone information

Advertising
background image

Digital Monitoring Products

XR500 Series Canadian Programming Guide

72

APPENDIX

23.12.2 LX-Bus Zone Type Defaults

These are complete spellings of the abbreviations used for the

zone types, such as Night and Exit.
Type - These are the abbreviations used for the zone types,

such as NT and EX.
Area - For an Area or Home/Sleep/Away with Guest system

this is 1 to 32. For an All/Perimeter or Home/Sleep/Away

system, this is the Interior, Bedroom, or Perimeter. Select the

area for NT, DY, EX, A1, A2, and AR types.
Fire Bell Out - Only available for FI, FV, and SV zones. Use

any output zone number listed.
Wireless - This indicates wireless equipment is being used.
DMP Wireless - These options are for use with the DMP 1100X

Wireless Receiver.
FA Series Wireless - These options are for use with the

FA400-DMP Remote Wireless Receiver.
Message - A = alarm report, T = trouble report,

L = local, no report,

(dash) = no report,

D = door propped (When SV zone is connected to 303 Silence/

Reset Switch), S = sensor reset/alarm silence, C = early

morning ambush cancel.
Output - These are 1 to 6 on-board and 500 to 999 off-board

relay outputs, 450 to 474 and 480 to 499 wireless outputs, D1

to D16, and G1 to G20.
Action - This selects the action of the output:

S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically bypassed after a

programmed number of trips.
Prewarn - This selects the keypad address that sounds the

entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the

default for this zone.
Retard Delay - Provides a programmed retard time before an

alarm initiates from a shorted zone. When used on an arming

zone, the retard delay occurs when the zone is shorted before

the armed state has changed. If the arming zone has Maintain

as the Style, the retard delay also occurs when the zone

returns to a normal state.
Presignal - Provides a keypad tone for zones in retard delay.

Retard must be YES before Presignal can be selected.
Fast Response - Provides a 167ms zone response instead of

the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 574 zones.
Priority - Requires this zone to be in a normal condition

before the area can be armed.
Style - The abbreviations for arming zone style:

TGL = Toggle, ARM = Arm only, DIS = Disarm only,
STEP = Wireless arming, MNT = Maint

Style

TGL

ARM

DIS

ST

EP

MNT

TGL

*Output

Options:

1

to

6,

450

to

474,

480

to

499,

500

to

999,

D1

to

D16,

G1

to

G20.

+

=Set

retard

to

YES

before

selecting

presignal.

=Zone

functions

not

a

va

ila

bl

e.

Door Number

0

to

16

0

0

0

0

0

Real-T

ime R

eports

N

or

Y

N

N

N

N

N

Follow Area

0

to

16

0

0

0

0

Priority

N

or

Y

N

N

N

N

N

N

N

N

N

N

Cross Zone

N

or

Y

N

N

N

N

N

N

N

N

N

Fast Response

N

or

Y

N

N

N

N

N

N

N

N

N

N

Presignal

1

to

16

+

+

+

+

+

Retard Delay

N

or

Y

N

N

N

N

N

Entry Delay

1

2 3 or

4

1

Prewarn

1

to

16

1-16

Swinger

N

or

Y

Y

Y

Y

N

N

N

N

N

N

N

Armed Short

Action

S

P

M

F

S

S

S

S

S

S

S

S

S

S

Output

*

0

0

0

0

0

0

0

0

0

0

Message

A T L – D S C

A

A

A

A

A

A

A

A

A

A

Armed Open

Action

S

P

M

F

S

S

S

S

S

S

S

S

S

S

Output

*

0

0

0

0

0

0

0

0

0

0

Message

A T L – D S C

A

A

A

A

A

A

A

A

A

A

Disarmed

Short

Action

S

P

M

F

S

S

S

S

S

Output

*

0

0

0

0

0

0

0

Message

A T L – D S C

T

A

A

A

A

Disarmed

Open

Action

S

P

M

F

S

S

S

S

S

Output

*

0

0

0

0

0

Message

A T L – D S C

T

T

T

FA

Series

W

ireless

Normally Open

N

or

Y

N

N

N

N

N

N

N

N

N

N

N

End-of-Line

N

or

Y

N

N

N

N

N

N

N

N

N

N

N

INT Contact

N

or

Y

N

N

N

N

N

N

N

N

N

N

N

Check-in T

ime

None

10

30

60

60

60

60

60

60

60

60

60

60

60

60

DMP

W

ireless

1126 Sensitivity

Low

or

High

Low

Low

Low

Low

Low

Low

Low

Low

Low

Low

Low

1126 Pulse

Count

2

or

4

4

4

4

4

4

4

4

4

4

4

4

1126 Disarm/

Disable

N

or

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

1142 LED

Operation

N

or

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Supervision Time

0

3

60

240

240

240

240

240

240

240

240

240

240

240

240

1114 Contact

1

2

3

4

1

1

1

1

1

1

1

1

1

1

1

1101 EXT

Contact N/O?

N

or

Y

N

N

N

N

N

N

N

N

N

N

N

1101 Contact

INT

or

EXT

INT

INT

INT

INT

INT

INT

INT

INT

INT

INT

INT

Wireless

N

or

Y

N

N

N

N

N

N

N

N

N

N

N

Fire Bell

Output

*

0

0

0

Area

INT

PERIM

BDRM

or

1

to

32

Type

--

NT

DY

EX

FI

PN

EM

SV

A1

A2

FV

AR

NT

DY

EX

FI

PN

EM

SV

A1

A2

FV

AR

XR500 Series LX-Bus Zone Information

Assi

gn

Di

sarm

condi

tion

for

NT

,

D

Y,

EX,

A1,

and

A2

onl

y.

Assi

gn

Pr

ew

arn

and

Entry

Del

ay

for

EX

onl

y.

Assi

gn

Retar

d

and

Pr

esi

gnal

f

or

FI,

SV

, A1,

A2,

and

PN

onl

y.

Zone T

ype

Defaults

NIGHT

D

AY

EXIT

FIRE

PANIC

EMERGENCY

SUPER

VISOR

Y

AUXILIAR

Y

1

AUXILIAR

Y

2

FIRE VERIFY

ARMING

Advertising