Digital Monitoring Products

XR500 Series Canadian Programming Guide

64

APPENDIX

Serial Number

This number is the network communicator serial number. Reference this number for communicator date-

of-manufacture, hardware version, etc. Press any top row Select key to display the Serial Number. Press

the COMMAND key to view the next prompt.
Current Flash

This option displays Flash 1 or Flash 2 indicating which physical flash chip the panel is currently using. Press any

top row Select key to display the current flash information. Press the COMMAND key to view the next prompt.
Communication Status

This option tests the individual components of cellular or network communication. The displayed results

are shown below.
Cellular Results:

Successful Display

Failure Display

MODEM OPERATING

NO MODEM FOUND

SIM CARD READ

NO SIM CARD

TOWER DETECTED

NO TOWER

SIM REGISTERED

NOT REGISTERED

This displays the cellular signal strength of the nearest tower for the SIM card carrier.

The

▐’s represent the signal strength 0-7. Select YES to continue through the remaining

component tests. Select NO to stop testing and return to the COMM STATUS prompt.

Successful Display

Failure Display

APN ACCEPTED

APN ERROR

COMM PATH GOOD

NO ACK RECEIVED

Network Results:

Successful Display

Failure Display

LINK OK

LINK ERROR

DHCP OK

DHCP ERROR

GATEWAY FOUND

NO GATEWAY

DEST FOUND

NO DESTINATION

COMM PATH GOOD

NOT CONNECTED

NO ACK RECEIVED

Cellular Signal Strength (CELL SIGNAL)

This option provides a way to test the cellular signal strength of the nearest tower

for the SIM card carrier. Press any top row Select key to display cell signal strength.

The X’s represent the numerical value of the cell signal strength in -dBm. The

▐’s

represent the signal strength 0-7.

Email Status

The Email Status menu, located in Diagnostics, tests each component of the panel’s e-mail

communication. The test proceeds until the first component failure or until all components have been

tested with positive results. The test screen displays after each component and displays for two seconds

or until the CMD key has been pressed. The displayed results are shown below.
Email Results:

Successful Display

Failure Display

Successful Display

Failure Display

EMAIL ENABLED

EMAIL DISABLED

FROM ADDR SENT

FROM ADDR FAILED

LINK OK

LINK ERROR

DEST ADDR SENT

DEST ADDR FAILED

SMTP SERVER OK

INVALID SERVER

DATA MODE SENT

DATA MODE FAILED

DEST ADDRESS OK

DEST ADDR FAILED

MESSAGE SENT

MSG SEND FAILED

CONNECTING

CANNOT CONNECT

DISCONNECTED

DISCONNECT FAIL

AUTH MODE SENT

AUTH MODE FAILED

EMAIL SUCCESS

PASSWORD SENT

BAD PASSWORD (or USERNAME)

Activate Cell
To begin the cellular activation for a 463C Interface Module, verify that the 463C has been added to panel

programming using Remote Link or by calling Customer Service (1-800-641-4282). Next, press any top row

Select key when

ACTIVATE CELL is displayed on the keypad. When the SURE NO YES? confirmation menu

appears press the Select key beneath YES to complete the cellular activation.

Note: This option only displays if a 463C Interface Module is attached to the panel.

Successful Display

Failure Display

CELL ACTIVATED

NOT ACTIVATED

SIGNAL: ▐▐▐▐▐▐▐

CONTINUE? NO YES

-XX dBm

SIGNAL: ▐▐▐▐▐▐▐