APPENDIX
23.14 Area Account Number Messages

XR500 systems send an area account number instead of the system account number with the following

panel messages/events based on the area assigned to the zone that initiated the alarm:
• WARNING: Alarm Bell Silenced (S34)
• Abort Signal Received (S45)
• Cancel Signal Received (S49)
• ALERT: System Recently Armed (S78)
• ALERT: Exit Error (S80)
• ALARM: Verify Signal Received (S96) (not currently sent on area arming systems)

The XR500 has always sent the area account number for the following messages:
• Zone event messages for all non-24 hour zones assigned to an area
• Arming
• Disarming

The XR500 sends the following messages using the area account number based on the lowest area number

in Display Areas programming from the keypad being used:
• User Code Add/Change/Delete
• Door Access/Denied
• User 1 Ambush and Early Morning Ambush
• System Test Begin/End
• Unauthorized Entry
• Service Code and Service Request

The XR500 sends the following messages using the area account number based on the area number:
• Late to Arm for area schedules