5  zone 3 rex strike time, 6  activate onboard speaker, 7  card options – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 29: 8  custom card definitions, 1 site code position, 2 site code length, 5 zone 3 rex strike time, 6 activate onboard speaker, 7 card options, 8 custom card definitions

Advertising
background image

Digital Monitoring Products

XR500 Series Canadian Programming Guide

20

DEVICE SETUP
6.18.3

RELOCK ON ZONE 2

CHANGE?

NO YES

Relock on Zone 2 Change?

Selecting NO leaves the relay on for the door access time when Zone 2 restores.

Selecting YES turns the 734/734N/734N-WiFi relay off and relocks the door when

Zone 2 changes state. The default is NO.

6.18.4

ACTIVATE ZONE 3

REX? NO YES

Activate Zone 3 Request to Exit

Selecting YES activates the Zone 3 Request to Exit (REX) option.
Selecting NO allows standard zone operation on Zone 3 and displays the ACTIVATE

ONBOARD SPEAKER option. Default setting is NO.
Optionally connect a PIR (or other motion sensing device) or a mechanical switch to

Zone 3 to provide REX capability to the system. When Zone 3

shorts, the on-board

Form C relay activates for the programmed number of seconds. During this time,

the user can open the protected door to start the programmed Bypass entry/exit

timer. After the programmed number of seconds, the relay restores the door to its

locked state.
The 734/734N/734N-WiFi module provides a bypass-only option for REX on Zone 3.

When Zone 3 opens from a normal state, only a Bypass occurs: the on-board relay

does not activate. This bypass-only option uses two methods of REX. The first REX

device provides the programmed Bypass entry/exit timer. The second REX device, or

manual device such as a door knob, unlocks the door.
An example of the bypass-only configuration is a door to an office that is locked 24

hours a day. Users pass a REX motion detector positioned by the door to begin the

programmed exit timer. Within the programmed number of seconds the user must

then manually activate a second device, such as a REX device or manual door knob,

to unlock the door. If the door is opened after the programmed number of seconds,

the zone goes into alarm.

6.18.5

ZN 3 REX STRIKE

TIME:

5

Zone 3 REX Strike Time

Enter the number of REX seconds to elapse. Range is from 5 to 250 seconds. Press

any top row select key to enter the number of seconds. The default is 5 seconds.
Press the COMMAND key to move forward to the ACTIVATE ONBOARD SPEAKER option.

The Back Arrow returns to ACTIVATE ZONE 3 REX.

6.18.6

ACTIVATE ONBOARD

SPEAKER? NO YES

Activate Onboard Speaker

Select YES to enable the onboard piezo speaker for local annunciation. Select NO to

turn the piezo off for all operations. This does not affect remote annunciator open

collector (RA) operation. The default is NO.

6.18.7

CARD OPTIONS:

DMP

Card Options

Press any top row Select key to display options. Press the select key under DMP,

CUSTOM or ANY to select that option. Select DMP to indicate the reader sends a 26-

bit DMP data string. Press the COMMAND key to display REQUIRE SITE CODE.

Note: When set to DMP, the 734/734N/734N-WiFi converts 17 bits of the 26-bit

data string into a 5-digit number.
Select CUSTOM if using a non-DMP card or user code length of 6 to 10 digits.

Default is DMP.

Select ANY to allow all card reads to activate the door strike relay. The door strike

relay is activated for the length of time programmed in ZN 3 REX STRIKE TIME. No

user code information is sent to the panel.

6.18.8

WIEGAND CODE

LENGTH: 26

Custom Card Definitions

Wiegand Code Length

When using a custom credential, enter the total number of bits to be received in

Wiegand code including parity bits.
Press any top row Select key to enter a number between 1-255 to equal the number

of bits. Default is 26 bits.
Typically, an access card contains data bits for a site code, a user code, and start/

stop/parity bits. The starting position location and code length must be determined

and programmed into the 734/734N/734N-WiFi Module.

CARD OPTIONS:

DMP CUSTOM ANY

Advertising