JT100/JT100 All Terrain Operator’s Manual

Systems and Equipment - 145

Driver/Loader Attachment

CMW

©

Optional Loader/Driver Remote Control

Problem

Possible cause

Possible solution

Loader/Driver operates at
full speed/No trigger control

Proportional valve manual
override screwed in

Unscrew manual override.

Trigger potentiometer voltage
too high

Adjust trigger voltage to 0.4-0.6V
when trigger is released and/or
replace.

Loader/Driver will not
operate with remote
pendant

No power

Check voltage at terminal 14.

Blown fuse

Check wiring; replace 8A fuse.

Amplifier not adjusted properly

Check amplifier setup and output.

Trigger potentiometer voltage
output not changing

Check trigger voltage output.

Power relay not operating
correctly

Check relay wiring.

Loader/Driver operation is
erratic

Power build-up solenoid wiring
loose

Check wiring at power build-up
solenoid.

Trigger potentiometer voltage
erratic

Check voltage output for smooth,
consistent change as trigger is pulled.

Wiring connections at terminal
strip, pendant, and receptacles

Check wiring connection; replace if
required.

Two functions operate at
the same time

Wires shorted together at
terminal strip, pendant head, or
receptacles.

Check wiring; replace wiring harness
if required.

Hydraulic contamination in
solenoid cartridge.

Remove and clean cartridge; clean
hydraulic system.